1. Place the softener where you want to install it, making sure it is on 

a clean, level and firm base.

2.  Do  all  necessary  plumbing  (inlet  to  inlet,  outlet  to  outlet,  and 

drain  line  to  drain).  The  control  valve,  fittings  and/or  bypass  are 

designed to accommodate minor plumbing misalignments but are 

not designed to support the weight of a system or the plumbing.

3. When assembling the installation fitting package (inlet and outlet), 

connect the fitting to the plumbing system first and then attach the 

nut, split ring and o-ring. Heat from soldering or solvent cements 

may damage the nut, split ring or o-ring. Solder joint should be cool 

and solvent cements should be set before installing the nut, split 

ring and o-ring. Avoid getting primer and solvent cement on any part 

of the o-rings, split rings, bypass valve or control valve.

4. A jumper ground wire should be installed between the inlet 

and  outlet  pipe  whenever  the  metallic  continuity  of  a  water 

distribution  piping  system  is  interrupted.  Install  grounding 

strap on metal pipes.

(All electrical & plumbing should be done in accordance to all local codes)

INSTALLATION INSTRUCTIONS

5. The drain connection may be made using either 5/8” polytube (see below) or a 3/4” female adapter. The polytube insert 

is shipped attached to the drain line elbow’s locking clip. Press the insert into the drain line tubing (tubing not provided). 

Loosen the nut of the drain line elbow. Press the 5/8” polytube with insert into the drain line elbow until it seats on the back 

of the fitting. Tighten the nut. If soldering, joints near the drain must be done prior to connecting the drain line flow control 

fitting. Leave at least 6” between the drain line control fitting and solder joints when soldering pipes that are connected on 

the drain line control fitting. Failure to do this could cause interior damage to the drain line flow control fitting. Never insert a 

drain line into a drain, sewer line, or trap. Always allow an air gap between the drain line and the wastewater to prevent the 

possibility of sewage being back-siphoned into the softener.

BRINE LINE FITTING CONNECTIONS

DRAIN LINE FITTING CONNECTION USING 5/8" POLY TUBE

Click to buy NOW!

PD

F-XCHANGE

w

ww

.docu-track.c

om

Click to buy NOW!

PD

F-XCHANGE

w

ww

.docu-track.c

om

POLYTUBE

Summary of Contents for X-FACTOR Series

Page 1: ...ars of trouble free service When installed in accordance with the following instructions and if given reasonable care clear soft water will be the result For servicing and future inspection purposes please file this booklet with your important documents 7 FESLX 24B 7 FESLX 32B 7 FESLX 45B 7 FESLX 60B 7 FESLXC 24B ELECTRONIC IRONSOFT WATER SOFTENER WITH THE X FACTOR CONTROL VALVE PROGRAMMED FOR PRE...

Page 2: ... for each ppm iron for total compensated hardness Use the total compensated hardness number for hardness setting on page 8 Total Grains of Compensated Hardness per Day INSTALLATION DATE SERIAL NUMBER INSTALLER NAME PHONE ADDRESS TABLE OF CONTENTS Job Specifications 2 Pre Installation Review 3 General Installation and Service Warnings 3 Bypass Valve Operation 4 Installation Instructions Diagrams 5 ...

Page 3: ...QUALITY If sand or sediment is present in the water supply a sediment filter should be installed ahead of the water softener Your water softener has been designed to adequately reduce compensated hardness from levels up to 100 grains per gallon Ferrous bicarbonate clear water and or ferric hydroxide red water iron levels up to 10 ppm can also be reduced Ferrous iron is dissolved in water and not v...

Page 4: ...rs are glass filled Noryl or equivalent and the nuts and caps are glass filled polypropylene All seals are self lubricating EPDM to help prevent valve seizing after long periods of non use Internal o rings can easily be replaced if service is required The bypass consists of two interchangeable plug valves that are operated independently by red arrow shaped handles The handles identify the flow dir...

Page 5: ...rical plumbing should be done in accordance to all local codes INSTALLATION INSTRUCTIONS 5 The drain connection may be made using either 5 8 polytube see below or a 3 4 female adapter The polytube insert is shipped attached to the drain line elbow s locking clip Press the insert into the drain line tubing tubing not provided Loosen the nut of the drain line elbow Press the 5 8 polytube with insert...

Page 6: ...PDF XCHANGE w w w docu track c o m C l i c k t o b u y N O W PDF XCHANGE w w w docu track c o m 6 The brine refill flow control assembly is installed in an easy to access refill elbow located on top of the control valve The refill flow control assembly is attached to the control valve with a locking clip The locking clip allows the elbow to rotate 270 degrees so the outlet can be oriented towards ...

Reviews: