17
●
30 inches is the minimum clearance between the top of the cooking surface and the
bottom of an unprotected wood or metal cabinet.
●
To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage
space located above the surface units should be avoided. If cabinet storage is to be
provided, the risk can be reduced by installing a range hood that projects horizontally a
minimum of 5 inches beyond the bottom of the cabinets.
●
Place your electric range on a floor that is strong enough to support it when it is fully
assembled as above picture. To level your electric range, adjust the leveling legs at the
bottom of the unit.
●
Avoid installing the unit in moist areas, ass this may result in the risk of electrical shock.
Installation of the Backsplash
1. Fix 2 screws (M4*8) to the corresponding hole at the back of cover, leaving
about 3mm gap (S1).
2. Put the backsplash plate on the cover make the big holes through the heads
of the screws (S2).
3. Push the backsplash plate making the small holes align the screws (S3).
4.
Tighten the screws use driver (S4).
Leveling the Range
The electric range must be installed levelly for proper operation. There are four screw-type
leveling legs at the bottom of the range for you to adjust the level of the range, rotating
Summary of Contents for LB-ERT24RC-S