• Lanaform® cannot be held liable in the event of accidental damage resulting from any use contrary to the instructions given in these instructions for use.
MAINTENANCE AND STORAGE
If the water contains too much calcium and magnesium, it may deposit a “white powder” in the device. If this foam is deposited on the transducer (ceramic ring producing ultrasounds,
diagram 1, point 3), this will prevent the device from working properly.
Maintenance:
We recommend:
1. Using cooled, boiled water for each use;
2. Cleaning the reservoir every 2 days and cleaning the transducer every week;
3. Changing the water in the reservoir every 2 days;
4. Cleaning the device and making sure that all its parts are completely dry when it is not in use.
To clean the transducer:
1. Switch the device off and unplug it;
2. Put 2 to 5 drops of vinegar on its surface and leave them there for 2 to 5 minutes;
3. Brush the foam off the surface with a soft brush (cotton bud) (21). Do not use a hard tool to scrape the surface;
4. Rinse the reservoir of the base in clean water;
5. Do not use soap, solvent or spray cleaner to clean the transducer.
To clean the reservoir:
1. Switch the device off and unplug it;
2. Clean the reservoir with water using a soft cloth and a little highly diluted vinegar if there are foam or limescale deposits on the inside. Do not use any corrosive detergents.
Rub the ceramic disc gently with a cotton bud, taking care not to scratch it; (22)
3. Rinse the reservoir in clean water.
Storage:
After cleaning and drying the device, store it in a dry, cool place out of the reach of children.
TROUBLESHOOTING
In the event of a malfunction, under normal conditions of use, please refer to the following chart:
Breakdowns
Possible causes
Solutions
No mist
The water level in the reservoir is too low.
Add water to the empty reservoir.
The temperature of the unit is too low.
Place the unit in a room at ambient temperature for half an hour
prior to use.
Mist has an unusual smell
The water has been standing in the reservoir too long.
Clean the reservoir and pour fresh water into it.
Low intensity
Too much/too little water in the reservoir.
Empty water out of the reservoir or add water to it.
Sediment on the transducer
Clean the transducer.
The water is too cold.
Use water that is at room temperature.
The water is not clean.
Clean the reservoir and pour fresh water into it.
EN
Summary of Contents for Mili
Page 1: ...Create your own style Trendy Unique...
Page 2: ......
Page 3: ...1 2 4 3 5 6 7 8 9 10...
Page 4: ...11 12 13 14 15 16...
Page 5: ...17 18 19 1X 2X...
Page 6: ...20 21 22...
Page 31: ...31 Mili Mili LANAFORM Mili 10 30 C 30 3 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 RU...
Page 33: ...33 Mili 3 4 Lanaform 1 3 1 2 3 4 1 2 2 5 2 5 3 21 4 5 1 2 22 3 RU...
Page 34: ...34 LANAFORM LANAFORM LANAFORM LANAFORM LANAFORM LANAFORM LANAFORM LANAFORM RU...
Page 47: ...47 Mili Mili Mili LANAFORM Mili 30 10 30 3 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 AR...
Page 49: ...49 Mili 4 3 Lanaform 3 1 1 2 3 4 1 2 5 5 2 3 21 4 5 1 2 22 3 AR...
Page 50: ...50 LANAFORM LANAFORM LANAFORM LANAFORM LANAFORM LANAFORM LANAFORM LANAFORM AR...
Page 59: ...59 Mili Mili LANAFORM Mili Mili 10 C 30 C 30 3 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 BG...
Page 61: ...61 Mili 3 4 Lanaform 1 3 1 2 2 3 2 4 1 2 2 5 2 5 3 21 4 5 1 2 22 3 BG...
Page 62: ...62 LANAFORM LANAFORM LANAFORM LANAFORM LANAFORM LANAFORM LANAFORM LANAFORM BG...
Page 67: ...67...