LAN Power LP-2340 Installation Manual Download Page 9

 

9

 

4.  Remove  and  re-apply  power  to  the 

device  and  check  the  indicators during 

power up sequence. 

A port indicator is 

not lit and the PSE 

(Power Supply 

Equipment) does 

not operate 

1.  The extender does not detect a PSE; and 

the port is not enabled. 

2.  Verify that the IP Device is designed for 

PoE operation (i.e. PoE Enabled). 

3.  Verify  that  you  are  using  a  standard 

Category  5/5e/6,  straight-wired  cable, 

with four pairs. 

4.  If  there  is  an  external  PoE  device 

connected, replace it  to  verify  that  it  is 

functioning properly. 

5.  Ensure that  the  input  Ethernet cable is 

connected to the 

“Data or PoE IN” RJ-45 

port. 

6.  Verify  that the PSE  is connected to  the 

“Data or PoE IN” port. 

7.  Try  to  reconnect the  same  PSE  into  a 

different  extender.  If  it  works,  there  is 

probably  a  faulty  port  or  RJ-45 

connection. 

8.  Verify that there is no shortcut over any 

of  the  twisted  pair  cables  or  over  the 

RJ45 connectors. 

The end device 

operates, but there 

is no data link 

1.  Verify that the port indicator on the rear 

panel is continuously lit. 

2.  If  an  external network device is  in  use, 

replace it with a good one. 

3.  Verify  that  for  this  link,  you  are  using 

standard  UTP/FTP Category  5  straight 

(non-crossover)  cabling,  with  all  four 

pairs. 

Summary of Contents for LP-2340

Page 1: ...2340 Internal Single Channel PoE and Ethernet Data Extender V 1 1 0 LAN Power 44240 Fremont Blvd Fremont Ca 94538 USATelephone 1 510 275 4572 FAX 1 510 284 2420 Web Site Address www lan power com Emai...

Page 2: ...it to us for repair WARNING This apparatus must be earthed Apparatus shall be connected to a mains socket outlet with a protective earthing connection To prevent fire or electric shock hazard do not...

Page 3: ...0 meters 328 feet per unit Data rate 10 100Mbps full duplex and is compliant with standard Ethernet protocols and devices IEEE802 3af PoE at PoE compliant passes PoE power throughout the channel Dual...

Page 4: ...4 Front view Rear view 12VDC Input Data PoE Input Data Output Data PoE Output Optional LP 2340PSU Input Data PoE Input Application Overview...

Page 5: ...e does not exceed 100 meters 328 ft There is no on off switch when connected correctly the LP 2340 is operational and no programming is required Connections 1 Connect the Data PoE IN RJ 45 port to you...

Page 6: ...n Transferring data at 10Mbps 100Mbps Unlit Data link is not connected Flashing green Transferring data at 100Mbps Output Indicators LED Color Indication 10Mbps Unlit Data link is not connected Flashi...

Page 7: ...IEEE802 3af PoE compliant Full duplex operation at the rate of 100 Mbps and 10 Mbps Fully compliant with IEEE 802 3TM IEEE 802 3u and IEEE 802 3ab standards Standards Conformance IEEE 802 3af and IEEE...

Page 8: ...hooting Symptom Corrective steps Extender does not power up 1 Verify that an approved power cable is used 2 If the extender is powered by a PoE switch or Midspan Injector make sure the switch is compl...

Page 9: ...ing properly 5 Ensure that the input Ethernet cable is connected to the Data or PoE IN RJ 45 port 6 Verify that the PSE is connected to the Data or PoE IN port 7 Try to reconnect the same PSE into a d...

Page 10: ...r higher 2 Using a Cat 5e 6 is recommended For further Technical Support call 1 510 275 4572 Note When calling Technical supportplease have Manufacturer Nameand PartNumbers for all devices being conne...

Page 11: ...at www lan power com LAN Power reserves the right to make changesin specificationsand other informationcontainedin thisdocument and its web site without prior notice The reader should consult LAN Powe...

Reviews: