LAN Power LP-2340 Installation Manual Download Page 6

 

6

 

PoE Device 

 

Indicators                                             

Input Indicators 

LED 

Color 

Indication 

48VDC  Input 

Unlit 

No  external  DC  power  source 

connected 

Steady  amber 

LP-2340PSU  connected 

PoE Active 

Unlit 

No 

PoE 

power 

sourcing 

equipment  connected  (No  PoE 

input)   

Steady  amber 

Incoming  PoE connected 

10Mbps 

Unlit 

Data link  is not  connected 

Flashing  green 

Transferring  data  at 10Mbps 

100Mbps 

Unlit 

Data link  is not  connected 

Flashing  green 

Transferring  data  at 100Mbps 

Output Indicators

 

LED

 

Color

 

Indication

 

10Mbps 

Unlit 

Data link  is not  connected 

Flashing  green 

Transferring  data  at 10Mbps 

100Mbps 

Unlit 

Data link  is not  connected 

Flashing  green 

Transferring  data  at 100Mbps 

Note: 

● If an IEEE 802.3af/at compliant PoE(PSE) device is connected to the 
input  port,  the  power  source  must  deliver  a  maximum  power  of 

15.4W/34.2W. 
● The maximum  input power is 48VDC.    

Specifications                                     

Summary of Contents for LP-2340

Page 1: ...2340 Internal Single Channel PoE and Ethernet Data Extender V 1 1 0 LAN Power 44240 Fremont Blvd Fremont Ca 94538 USATelephone 1 510 275 4572 FAX 1 510 284 2420 Web Site Address www lan power com Emai...

Page 2: ...it to us for repair WARNING This apparatus must be earthed Apparatus shall be connected to a mains socket outlet with a protective earthing connection To prevent fire or electric shock hazard do not...

Page 3: ...0 meters 328 feet per unit Data rate 10 100Mbps full duplex and is compliant with standard Ethernet protocols and devices IEEE802 3af PoE at PoE compliant passes PoE power throughout the channel Dual...

Page 4: ...4 Front view Rear view 12VDC Input Data PoE Input Data Output Data PoE Output Optional LP 2340PSU Input Data PoE Input Application Overview...

Page 5: ...e does not exceed 100 meters 328 ft There is no on off switch when connected correctly the LP 2340 is operational and no programming is required Connections 1 Connect the Data PoE IN RJ 45 port to you...

Page 6: ...n Transferring data at 10Mbps 100Mbps Unlit Data link is not connected Flashing green Transferring data at 100Mbps Output Indicators LED Color Indication 10Mbps Unlit Data link is not connected Flashi...

Page 7: ...IEEE802 3af PoE compliant Full duplex operation at the rate of 100 Mbps and 10 Mbps Fully compliant with IEEE 802 3TM IEEE 802 3u and IEEE 802 3ab standards Standards Conformance IEEE 802 3af and IEEE...

Page 8: ...hooting Symptom Corrective steps Extender does not power up 1 Verify that an approved power cable is used 2 If the extender is powered by a PoE switch or Midspan Injector make sure the switch is compl...

Page 9: ...ing properly 5 Ensure that the input Ethernet cable is connected to the Data or PoE IN RJ 45 port 6 Verify that the PSE is connected to the Data or PoE IN port 7 Try to reconnect the same PSE into a d...

Page 10: ...r higher 2 Using a Cat 5e 6 is recommended For further Technical Support call 1 510 275 4572 Note When calling Technical supportplease have Manufacturer Nameand PartNumbers for all devices being conne...

Page 11: ...at www lan power com LAN Power reserves the right to make changesin specificationsand other informationcontainedin thisdocument and its web site without prior notice The reader should consult LAN Powe...

Reviews: