2
Safety
Information
5
2.1
Proper use, conditions for use
Use
The LT 2/KS 1D lambda transmitter is a universal, microprocessor-based
measuring device for the direct measurement of the concentration of O2 and
flammable, oxidising gas constituents (CO/H
2
), referred to as CO equivalent (
COe ), in the superstoichiometric range in combustion systems (
l
>1 ), in
connection with the KS1-DK combination probe.
The system is designed for semi-automatic calibration with air and test gas.
If you are contemplating employing the measuring system for other purposes, and
cannot assess with certainty whether the device will function without problem in
this application, please first contact the manufacturer.
Preconditions
The preconditions for use are that system planning, assembly, installation,
commissioning, maintenance and repair work are carried out by adequately
trained personnel, and such work is checked by responsible expert members of
staff.
Expert handling
In particular, please ensure that:
• Use of the device conforms to the technical data and stipulations regarding
permitted use and assembly, connection, ambient and operating conditions
(contained in the order documents, user information, nameplates, etc.) and the
supplied documentation
• Local, system-specific circumstances and risks and regulations pertaining to
technical operation of the device are taken into consideration
• All necessary measures to preserve the value of the device, e.g. for transport
and storage, maintenance and inspection, are carried out.
Proper use
The product described herein left the factory in perfect condition, conforming to
technical safety regulations and having undergone inspections. In order to
maintain this condition, it may only be employed in the manner described by the
manufacturer. Likewise, suitable transport, storage and erection and careful
operation and maintenance are prerequisites for the perfect, safe operation of the
device.
This product must be installed and operated by appropriately qualified personnel,
who are familiar with this safety information and warnings and are able to act on
them faultlessly. Unqualified tampering with the device or non-compliance with
warnings herein or affixed to the device may result in severe bodily harm and/or
material damages.
Proper use of the device constitutes its use only for the applications referred to in
the technical description. Consequently, additional devices or devices from other
manufacturers must be recommended or approved by Lamtec.
Provided that the technical safety instructions and specifications for operation
contained in this Manual are observed, in normal circumstances this device does
not carry any risk of material damages or harm to health.