11
Remote control of parameters
If the REMOTE ENABLE parameter (Index n°5) is equal to 1, then it is possible to modify or activate some functions of the
projector, via DMX. The activation of controls is based on a precise time sequence of the DMX channels values, if a step of
the sequence is wrong, the procedure will be deleted.
All the STEPS of the following table must be executed.
STEP
DMX channels status
Timing
Action
1
CH1..CH5 = 0 4sec<time ------------------------------
2
CH1..CH5 = 0
CH6 = 255
2sec<time<4sec
------------------------------
3
CH1..CH5 = 0
CH6 = 0
2sec<time<4sec
------------------------------
4
CH1..CH5 = 0
CH6 = 255
2sec<time<4sec
------------------------------
5
CH1..CH5 = any
CH6 different from 0 and
from 255
2sec<time
The display flashes the number
222
to show the entrance in the
parameters remote control.
The coupling of the parameters and the DMX channels is as follow:
HP BLACKOUT
Æ
CH1
SHUT ON COLOUR
Æ
CH2
COLOUR CORRECTION
Æ
CH3
RAINBOW MODE
Æ
CH4
RESET
Æ
CH5
BOOLEAN PARAMETER
If the value of the DMX channel is minor than 9, the parameter will
remain the same.
If it is inclusive between 9 to 127, the parameter will be equal to 0.
If it is greater than 127, the parameter will be equal to 1.
NOT BOOLEAN PARAMETER
COLOUR CORRECTION
:
If the value of the DMX channel is minor than 9, the parameter will
remain the same.
If it is inclusive between 9 to 90, the parameter will be equal to 0
If it is inclusive between 91 to 171, the parameter will be equal to 1.
If it is greater than 171, the parameter will be equal to 2.
RAINBOW TYPE:
If the value of the DMX channel is minor than 10, the parameter
will remain the same.
If it is inclusive between 10 to 59, the parameter will be 0.
If it is inclusive between 60 to 109, the parameter will be 1.
If it is inclusive between 110 to 159, the parameter will be 2.
If it is inclusive between 160 to 209, the parameter will be 3.
If it is greater than 209, the parameter will be equal to 4.
6
CH1..CH5 = any
CH6 = 0
------------
The display will return to the usual visualized condition, to signal
the exit from the remote control. The values of the DMX channels at
the moment of the exit from the remote control condition will
modify in a permanent way the parameters to which those are
coupled.
N.B.
if the parameter
RESET has been set at 1 will be executed a
global reset procedure of the projector.