10
Stand alone mode (recordable dmx scenes)
To start this execution,
assign to Index n° 10 (PROGRAM EXECUTION) the value from
1
to
20
.
It is possible to create an inside program that allows the projector to function on "stand-alone" mode, it is necessary to have a
DMX controller to record the scenes.
When the "stand-alone" function is enabled, the projector becomes a DMX generator. It will supply via DMX line, the values
corresponding to the inside program.
The inside program runs a loop up to 20 steps (PROGRAM STEP); each step contains: a DMX value of all the channels of the
projector, a time slope to achieve the new step (STEP SLOPE) and a hold time of the step (STEP HOLD).
WARNING: The projector in stand alone mode becomes a DMX generator, it is necessary to disconnect that projector
by DMX controller or by the other projector MASTER because generates conflict in the signal.
Storing of the steps
•
Via the DMX controller, give to the projector the position and the image required
•
Set the value of STEP SLOPE (Index 12) to assign the time (in seconds) of the transition from the previous
step to this new one
•
Confirm with the ENTER button
•
Set the value of STEP HOLD (Index 13) to assign the time (in seconds) of the hold time of this new step
•
Confirm with the ENTER button
•
Assign to the PROGRAM STEP parameter (Index 11) the number of the step you want memorize
•
Push the ENTER button to store
Execution of the inside program
If the PROGRAM EXECUTION parameter (Index 10) contains "0", than the projector follows the command received from an
external DMX controller, otherwise, if it contains a value between "1" and "20", than the projector executes a loop of steps
from "1" to the number stored in the PROGRAM EXECUTION parameter.
Modification of the program during execution
If, during the execution of a program in "stand-alone" mode, you set a PROGRAM STEP value (Index 11) and then you push
the ENTER button, the program in execution will jump directly to the step required.
If, during the execution of a program in "stand-alone" mode, you set a STEP SLOPE value (Index 12) or a STEP HOLD value
(Index 13) and then you push the ENTER button, the corresponding parameter of the step in execution will be modified.
1
2
3
N
DMX
Time
Step 1
Step 2
Slope 1
Slope 2
Hold 1
Hold 2