background image

 

4

 

 

SAFETY INSTRUCTIONS 

 

3-1  GENERAL SAFETY INSTRUCTIONS 

 

  

The device may only be opened by a trained and qualified technician or electrician. 
Before opening the device remove the mains plug from the wall socket, and make sure 
that the machine is not receiving any electrical current. If you are unsure, or have any 
questions, always consult a trained and qualified technician or electrician. 

 

  

Before exchanging the LED module, remove the power supply plug. Only use original 
replacement LED modules from Lampert. 

 

  

Non qualified persons are prohibited by law from tampering with any electrical devices 
that are connected to the mains power supply, or otherwise receiving current. Non 
qualified persons may only operate the mains plug, power adapter or the main on/off 
switch. 

 

  

When carrying out repair or servicing work, the machine must always be disconnected 
from the power supply. Throughout any work of longer duration, that requires the 
qualified person to leave (even if only briefly) the place where work is being carried out, 
the wall socket must also be securely closed off. 
 

 

  

If it can be assumed that a safe operation of the device is no longer possible, then the 
machine must be shut down and removed from the power supply; it must also be 
secured against accidental re-operation or activation. 

 

  

It is likely, and can be expected, that a safe operation of the device is no longer possible 
when: 

 

  

 -  The machine will not operate. 

 

  

 -  When malfunctions occur. 

 

  

 - The machine will operate, but shows visible signs of damage. 

 

 

 

 

 

 

 

3-2  PERSONAL SAFETY AND POTENTIAL RISKS 

 

 

  

EYE PROTECTION DURING WELDING 

 

  

Do not look into the arc without adequate eye protection. Only use a welders’ 
protective glare shield that contains a protective glass which conforms to 
regulations (protection class 11, minimum). 

 

 

The electric arc radiates rays of heat and light that can cause the user to be burned or 
dazzled. In Addition to this, the arc also gives off UV-radiation. If the eyes are not 
adequately protected, these invisible ultraviolet rays can cause a very painful 
conjunctivitis, the effects of which are only noticeable several hours after exposure. 

 

 

Those lingering or working in close proximity to the electric arc, must be made aware of 
the risks, and supplied with the appropriate protective equipment. Wherever necessary, a 
protective screen should be erected. 

 

 

 

 

 

EYE PROTECTION WHILST OPPERATING THE LED LAMP  

 

 

Do not look into the LED Lamp, or into the reflection of the LED light, without eye 
protection. Always use a welders’ protective glare shield with a minimum 
protection class of 3. 

 

 

 

Summary of Contents for USM

Page 1: ...and then only for its designated use and in accordance with the guidelines here within The manufacturer accepts no responsibility and is in no way liable for damage caused by improper use or operatio...

Page 2: ...tting the viewing distance 7 5 3 Focussing 8 5 4 Dioptre settings 8 6 CARE AND MAINTENANCE 6 1 Maintenance of the optical components 8 6 2 Maintenance of the electrical components 9 7 TROUBLE SHOOTING...

Page 3: ...her application of the appliance other than the above stated is prohibited It is prohibited to use this apparatus out of doors Use only in dry surroundings 2 INTRODUCTION Arc welding without protectiv...

Page 4: ...st be shut down and removed from the power supply it must also be secured against accidental re operation or activation It is likely and can be expected that a safe operation of the device is no longe...

Page 5: ...parts must not be put together using excessive force Mount the bearing rod 11 to the base plate 13 using the bolt that is included tighten it with an open ended spanner Place upright on a clean flat a...

Page 6: ...n the welding device will run a self test During the self test the LCD glare protection filter Shutter 6 will change from its clear setting to its dark setting and back again Each time the machine is...

Page 7: ...CD glare protection filter Shutter 18 Rod for pitch adjustment 5 INSTRUCTIONS FOR USE 5 1 FIRST STEPS Adjust the height and position of the supporting arm 12 so that when both hands are resting on the...

Page 8: ...t eye piece tube 3 In the normal position the lower part of the sleeve is aligned with the marking on the eye piece tube When a user s eyes have differing strengths of vision With only the right eye o...

Page 9: ...S Warning Danger of glare never look directly into the LED light or its reflections Caution Only operate the LED light when the LED module is mounted in the supporting arm of the hand piece Changing t...

Page 10: ...h the other 13 Always hold the microscope upright 8 TECHNICAL DATA 8 1 TECHNICAL INFORMATION MICROSCOPE LCD glare protection filter and LED light module For use only in conjunction with PUK U3 precisi...

Page 11: ...vice may only be opened by a trained and qualified technician Text pictures and illustrations represent the technical stand at the time of printing we reserve the right to make changes as necessary 9...

Page 12: ...ns of the above mentioned directive including any amendments hereof that were valid at the time of declaration Relevant EC guidelines According to low voltage directive 2006 95 EG According to EMV ele...

Reviews: