Degree of protection 

IP 20 

 

 

 

Weight 

3,6 kg 

  

8-2

 

OPTICAL INFORMATION - MICROSCOPE 

 

  

 

 

Lens 

1,0 

  

 

 

Eye-piece lenses 

10x 

  

 

 

Working distance 

variable 

 

 

 

Degree of magnification 

10x 

 

 

 

Size of “field of vision” in mm 

20 mm 

 

8-3

 

TECHNICAL INFORMATION - LCD SHUTTER 

 

 

 

 

Degree of luminescence 

DIN 3 

 

 

 

Degree of Obscurity 

DIN 11 

 

 

 

Switching time 

<50ms 

 

 

 

UV protection 

>UV 15 

 

 

 

IR protection 

>IR 14 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

Warning!

 

 

   The device may only be opened by a trained and qualified technician! 

  

  

Text, pictures and illustrations represent the technical stand at the time of printing; we reserve the 
right to make changes as necessary. 

 

 

 

 

 

 

 

  

DISPOSAL INFORMATION: 

  

  

Devices that are no longer in use (waste) can be made unserviceable by removing the 
mains power cable. 

  

  

For EU countries only: 

  

  

As specified in European directive 2002/96/ EG on waste electrical and electronic 
equipment, used electrical appliances must be collected and stored separately and 
introduced into an environmentally compatible disposal system. 

 

 

 

 

 

 

 

 

 

Summary of Contents for USM

Page 1: ...and then only for its designated use and in accordance with the guidelines here within The manufacturer accepts no responsibility and is in no way liable for damage caused by improper use or operatio...

Page 2: ...tting the viewing distance 7 5 3 Focussing 8 5 4 Dioptre settings 8 6 CARE AND MAINTENANCE 6 1 Maintenance of the optical components 8 6 2 Maintenance of the electrical components 9 7 TROUBLE SHOOTING...

Page 3: ...her application of the appliance other than the above stated is prohibited It is prohibited to use this apparatus out of doors Use only in dry surroundings 2 INTRODUCTION Arc welding without protectiv...

Page 4: ...st be shut down and removed from the power supply it must also be secured against accidental re operation or activation It is likely and can be expected that a safe operation of the device is no longe...

Page 5: ...parts must not be put together using excessive force Mount the bearing rod 11 to the base plate 13 using the bolt that is included tighten it with an open ended spanner Place upright on a clean flat a...

Page 6: ...n the welding device will run a self test During the self test the LCD glare protection filter Shutter 6 will change from its clear setting to its dark setting and back again Each time the machine is...

Page 7: ...CD glare protection filter Shutter 18 Rod for pitch adjustment 5 INSTRUCTIONS FOR USE 5 1 FIRST STEPS Adjust the height and position of the supporting arm 12 so that when both hands are resting on the...

Page 8: ...t eye piece tube 3 In the normal position the lower part of the sleeve is aligned with the marking on the eye piece tube When a user s eyes have differing strengths of vision With only the right eye o...

Page 9: ...S Warning Danger of glare never look directly into the LED light or its reflections Caution Only operate the LED light when the LED module is mounted in the supporting arm of the hand piece Changing t...

Page 10: ...h the other 13 Always hold the microscope upright 8 TECHNICAL DATA 8 1 TECHNICAL INFORMATION MICROSCOPE LCD glare protection filter and LED light module For use only in conjunction with PUK U3 precisi...

Page 11: ...vice may only be opened by a trained and qualified technician Text pictures and illustrations represent the technical stand at the time of printing we reserve the right to make changes as necessary 9...

Page 12: ...ns of the above mentioned directive including any amendments hereof that were valid at the time of declaration Relevant EC guidelines According to low voltage directive 2006 95 EG According to EMV ele...

Reviews: