Lampert Werktechnik GmbH
Lampert Werktechnik GmbH
OPERATING MANUAL PUK 5.1
EN
The activated material is shown in blue. At the bottom edge of the display, the desired welding situation
is selected by pressing on the symbol. Here too, selection of the symbol is confirmed in blue. The following
geometries or welding situations are available for selection:
♦
Universal setting for material thicknesses from 0.3 mm.
♦
Setting for thin sheet metal or wire parts equal to or less than 0.3 mm. This setting offers very
low development of heat, especially for short welding times (≤ 0.3 mm).
♦
Welding in sharp angles and tight joint situations. Here it is IMPORTANT to use short welding
times.
♦
Melting of welding wire. Use identical alloy wire with a diameter of 0.3 to 0.4 mm. Ideal is a
diameter of 0.35 mm.
♦
Application of welding wire on claws and stone settings. Particularly low-energy melting of
welding wire, diameter of approx. 0.2 mm recommended.
After selecting the material and the welding situation, the recommended power and pulse duration parameters
are set. The recommendation ranges are each marked with a thin blue line on the recommendation scale.
The red range stands for parameters that experience has shown do not permit the desired welding results
and that should be avoided. The power and pulse duration parameters can be adjusted with the swipe function
on the one hand, and on the other hand set to discrete values with the aid of the multifunctional controller.
The power is displayed as a percentage of the total power here, whilst the pulse duration is provided
in milliseconds. Pressing the multifunctional controller once switches between the power scale and the pulse
duration. The respective scale is then displayed as active, and the parameters can be selected. After around
one second, the power scale is activated again as standard. This means it is simple to perform power scale
readjustments, without needing to look away from the microscope.
6.7 Settings
In the "settings" user level, it is possible
to implement basic settings and perform various
test functions. The activated settings are shown
in blue.
18