Lampert PUK SM Operating Instructions Manual Download Page 8

 

SECTION 5 – OPERATION AND INSTRUCTIONS 

 
5-1. UNPACKING 

 
All stereo microscope components have been packaged carefully so that you can receive 
them in perfect condition.  We recommend that you keep the packaging material. It may be 
required again should you have to send in the microscope or wish to store it for a longer 
period, or whenever the mircoscope needs to be transported to a technical customer service 
center for maintenance or repair.   

 

Packaging includes: 
 

 

SMZ-140 (binoculars): A base with a tripod column to add a movable, lighted upper 
component. A binocular top section with eyepieces, eyepiece covers and a 
protective cover for the microscope   

 

Please remove and handle all microscope components very carefully.  

 

 

Avoid touching the lenses and optical elements. Also avoid contact with dust, water and 
other dirt-causing substances, as they can smudge or damage the lens surface and affect 
image quality.  

 

 
 

 

5-2. ASSEMBLY AND START-UP 

 

Please perform all work stages involved in assembling the stereo microscope very 
carefully.  The stereo microscope’s individual parts and elements should not be 
assembled too forcefully. 

 

 

  Place the base of the microscope (9) upright on a flat, clean and secure surface  

 Move 

the

 

attachment support

 

(17) over the tripod rod (19) and screw it on tightly. 

  Mount the adjusting ring (18) under the attachment support 

  Move the face protector (25) over the microscope head 

  Place the microscope head (10) into the head support

 

and screw it on from both sides  

  Screw on the ancillary lens

 

(objective) (6)   

  Screw the shutter (7) on to the ancillary lens and secure it into the correct position using 

the bolt

 

(23)  

  Plug the light plug (12) into the socket on the top side of the tripod  

  Connect the control line (20) to shutter with the welding device  

  Assemble the welding table (8) and mount it on the tripod base (Fig.  2) 

  Connect the connective lamp cable to the transformer 

  Insert the mains plug into a suitable electrical outlet.  

WARNING: Before connecting the stereo microscope to the electricity supply, 
check that the electricity supply voltage is compatible with the voltage labelled on 
the stereo microscope. 

 

  During a self-test immediately after switching on the welding device, the shutter 

(7) 

will 

quickly turn dark and then light again. Run this test each time prior to beginning your 
work, to ensure that the view protection filter functions perfectly. If needed, start the self-
test again by turning the welding device off and then on again. 

 
WARNING: Keep a minimum 50 mm distance between the light and the workpiece 
and/or the welding table.

 

 
 

ATTENTION! 

 

Before welding, always check that the protective filter (shutter) 
functions properly.

 

 
 

Summary of Contents for PUK SM

Page 1: ...PUK SM STEREO ZOOM MICROSKOPE OPERATING INSTRUCTIONS Lampert Tools USA Inc 115 V...

Page 2: ......

Page 3: ...e Operation of the device should only be done by trained professionals and be operated according to the intended purpose of use The manufacturer is in no way responsible for any damage caused by impro...

Page 4: ...ments 7 5 4 Operation 8 SECTION 6 CARE AND MAINTENANCE 9 6 1 Routine Maintenance 9 6 2 Maintenance of optic components 10 6 3 Maintenance of electrical components 10 6 4 Maintenance of mechanical comp...

Page 5: ...on of the cornea and irreversible clouding of the eye lens cataracts The PUK SM with its integrated LCD welder view protection filter offers reliable protection against these dangers and permanently p...

Page 6: ...aviolet rays cause very painful conjunctivital inflammation noticable after several hours Any persons or helpers who are working near the arc should also be made aware of the dangers and be equipped w...

Page 7: ...Code for Safety in Welding and Cutting CSA Standard W117 2 from Canadian Standards Association Standards Sales 178 Rexdale Boulevard Rexdale Ontario Canada M9W 1R3 phone 800 463 6727 or in Toronto 416...

Page 8: ...upport 17 over the tripod rod 19 and screw it on tightly Mount the adjusting ring 18 under the attachment support Move the face protector 25 over the microscope head Place the microscope head 10 into...

Page 9: ...port screw 2 Diopter regulator 3 Eyepiece tubes 5 Attachment holder adjustment knob 17 Head support attachment support 18 Adjusting ring 19 Tripod column 12 Lighting cable 4 Prisma casing 11 Zoom knob...

Page 10: ...ld be adjusted individually for each user C Focussing 1 Use the zoom button 11 to set the lowest enlargement setting 1x 2 Place a flat object in the middle of the welding table 8 3 Turn the focus knob...

Page 11: ...button 11 to set the lowest enlargement setting 4x 2 Although the stereo microscope comes with a parfocal setting the focus must be adjusted since lenses with lower zooms offer larger field depths Fie...

Page 12: ...lectrical components 1 Changing the lamp units a Unscrew the protective tube and the lamp shade of the lighting unit 13 by turning in a counter clockwise direction and removing it from the lamp frame...

Page 13: ...tion to electrical supply Insert lamp properly Replace lamp Have professionally repaired 7 2 IMAGE QUALITY PROBLEM CAUSE SOLUTION Poor resolution Eyepiece is dirty Lens is dirty Clean eyepiece Clean l...

Page 14: ...ned by trained personnel only SECTION 9 TECHNICAL DATA 9 1 Microscope technical data The microscope is equipped with an optical visor and lighting to use with the PUK Spot Welding Device Use only in d...

Page 15: ...horized dealers only Defective products are repaired free of charge if returned to an authorized dealer The Purchaser shall assume all transport costs DUE TO POSSIBLE MODIFICATIONS OR IMPROVEMENTS DUR...

Reviews: