Lampert PUK SM Operating Instructions Manual Download Page 12

 

10

 

6-2. Maintenance of optic components 

 

Do not disassemble optic components.  Please contact your local customer technical sevice to 
handle repairs not covered by these instructions.   

 

Before cleaning the lens surface, first remove dust using a special brush or pressurized air.  
Suitable cleaning tools may be purchased from any camera shop.   

 

1.  Cleaning the eyepieces   

 

a. Do 

not remove the eyepieces (1) from the eyepiece tubes (3). 

 

b.  Clean the outer surfaces and breathe on them while doing so.  

 

c.  Then dry the lens using special paper.  Dry the lens using circular motions from the center to 

the outside edges.  Do not wipe lenses that are already dry since lenses are very easily 
scratched.    

 

2.  Cleaning the lens. 

 

a.  Do not remove the lens from the microscope. 

 

b.  Clean the surfaces only. To clean, use a soft cotton cloth moistened with xylol / xylene.  Then 

use the same cloth to dry the lens.   

 
 
 

6-3. Maintenance of electrical components 

 

1.  Changing the lamp units 
 

a.  Unscrew the protective tube and the lamp shade of the lighting unit (13) by turning in a 

counter-clockwise direction and removing it from the lamp frame.    

 

b.  Carefully use a cloth to pull the lamp from the holder and insert a new lamp.  

 

c.  Replace the lampshade by turning in a clockwise direction and screwing it into the lamp 

holder.   

 

d.  The lamp must be cleaned if accidently touched with bare hands, otherwise the illuminative 

power and life span of the lamp will be affected.   

 

 
 

 

6-4. Maintenance of mechanical components 

 

1.  Adjusting the focus tension. 

 

The tension is pre-adjusted by the manufacturer.  At an optimal tension point, the focus 
head moves easily without the attachment sliding downwards due to its own weight.  

 

 

 

The focus tension ring (Fig. 1) is located between the focus knob (15) and the head 
support (17). 

 
 

a. 

To increase tension, turn the tension ring by using the tool included (Fig. 3) and turning in 
a clockwise direction (A); to reduce tension turn in a counter-clockwise direction (B). 

 

 

b. 

If the tool is not included, a suitable metal pin may be used.  

 

 
 
 

Summary of Contents for PUK SM

Page 1: ...PUK SM STEREO ZOOM MICROSKOPE OPERATING INSTRUCTIONS Lampert Tools USA Inc 115 V...

Page 2: ......

Page 3: ...e Operation of the device should only be done by trained professionals and be operated according to the intended purpose of use The manufacturer is in no way responsible for any damage caused by impro...

Page 4: ...ments 7 5 4 Operation 8 SECTION 6 CARE AND MAINTENANCE 9 6 1 Routine Maintenance 9 6 2 Maintenance of optic components 10 6 3 Maintenance of electrical components 10 6 4 Maintenance of mechanical comp...

Page 5: ...on of the cornea and irreversible clouding of the eye lens cataracts The PUK SM with its integrated LCD welder view protection filter offers reliable protection against these dangers and permanently p...

Page 6: ...aviolet rays cause very painful conjunctivital inflammation noticable after several hours Any persons or helpers who are working near the arc should also be made aware of the dangers and be equipped w...

Page 7: ...Code for Safety in Welding and Cutting CSA Standard W117 2 from Canadian Standards Association Standards Sales 178 Rexdale Boulevard Rexdale Ontario Canada M9W 1R3 phone 800 463 6727 or in Toronto 416...

Page 8: ...upport 17 over the tripod rod 19 and screw it on tightly Mount the adjusting ring 18 under the attachment support Move the face protector 25 over the microscope head Place the microscope head 10 into...

Page 9: ...port screw 2 Diopter regulator 3 Eyepiece tubes 5 Attachment holder adjustment knob 17 Head support attachment support 18 Adjusting ring 19 Tripod column 12 Lighting cable 4 Prisma casing 11 Zoom knob...

Page 10: ...ld be adjusted individually for each user C Focussing 1 Use the zoom button 11 to set the lowest enlargement setting 1x 2 Place a flat object in the middle of the welding table 8 3 Turn the focus knob...

Page 11: ...button 11 to set the lowest enlargement setting 4x 2 Although the stereo microscope comes with a parfocal setting the focus must be adjusted since lenses with lower zooms offer larger field depths Fie...

Page 12: ...lectrical components 1 Changing the lamp units a Unscrew the protective tube and the lamp shade of the lighting unit 13 by turning in a counter clockwise direction and removing it from the lamp frame...

Page 13: ...tion to electrical supply Insert lamp properly Replace lamp Have professionally repaired 7 2 IMAGE QUALITY PROBLEM CAUSE SOLUTION Poor resolution Eyepiece is dirty Lens is dirty Clean eyepiece Clean l...

Page 14: ...ned by trained personnel only SECTION 9 TECHNICAL DATA 9 1 Microscope technical data The microscope is equipped with an optical visor and lighting to use with the PUK Spot Welding Device Use only in d...

Page 15: ...horized dealers only Defective products are repaired free of charge if returned to an authorized dealer The Purchaser shall assume all transport costs DUE TO POSSIBLE MODIFICATIONS OR IMPROVEMENTS DUR...

Reviews: