11
6
INSTRUCTIONS
6-1 WELDING INSTRUCTIONS
Connect the clamp to a blank metal location on the work piece
or
Make sure there is good contact between work piece and welding table
Touch the electrode tip to the spot to be welded until the welding is done
without, or with minimum pressure to the electrode tip!
The welding procedure is automatically done:
o Safety gas encases the welding spot
o A signal announces the arc
o The light arc appears
o Safety gas supply ceases
The welding procedure may be stopped anytime by removing the electrode from the work
piece
6-2 IN GENERAL AND POINTERS
Important!
Always work with sharpened electrodes!
This is the best way to achieve maximum results.
Make sure the work piece has enough contact to the clamp. If
contact problems occur, make sure the clamp is in contact with a
metallic blank location.
Never weld „hands free“, this means; support both hands i.e. on the
workbench during welding. Shaking hands falsify the parameters of
the device. .
Apply only minimum pressure onto the electrode tip.
Weld only with minimum gas pressure!
2 to 4 l/min are often sufficient.
TIPS
Take enough time to get to know your device.
Try out various power levels of the device.
Keep in mind that various materials react differently during welding.