TRACER

ORP POCKETESTER

TM

CODE 1742

Table of Contents

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Parts & Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Meter Description

Front Panel Description . . . . . . . . . . . . . . . . . . . . . 5
TRACER Display. . . . . . . . . . . . . . . . . . . . . . . . . 5

Basic Operation

Powering the TRACER . . . . . . . . . . . . . . . . . . . . . 6
Electrode Recognition . . . . . . . . . . . . . . . . . . . . . . 6
Automatic Calibration . . . . . . . . . . . . . . . . . . . . . . 6
Data Hold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

ORP Testing

Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
ORP Display . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . 6
ORP Measurement . . . . . . . . . . . . . . . . . . . . . . . . 6
Storing Readings . . . . . . . . . . . . . . . . . . . . . . . . . 7
Recalling Stored Readings . . . . . . . . . . . . . . . . . . . . 7

Maintenance

Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Battery Replacement . . . . . . . . . . . . . . . . . . . . . . . 8
Cleaning & Conditioning the Electrode . . . . . . . . . . . . . 8

Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Replacing the Electrode . . . . . . . . . . . . . . . . . . . . . . . . 9
Expand Your TRACER . . . . . . . . . . . . . . . . . . . . . . . . 10
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

3

Summary of Contents for 1742 PockeTester

Page 1: ...TRACER POCKETESTER ORP CODE 1742...

Page 2: ......

Page 3: ...asic Operation Powering the TRACER 6 Electrode Recognition 6 Automatic Calibration 6 Data Hold 6 ORP Testing Overview 6 ORP Display 6 Getting Started 6 ORP Measurement 6 Storing Readings 7 Recalling S...

Page 4: ...unction LCD with Bar graph Operating Conditions 32 to 122 F 0 to 50 C and 80 RH ORP Range Accuracy 999mV 4mV Measurement storage 15 tagged numbered readings Power Four CR2032 button batteries see Page...

Page 5: ...Battery compartment cap 2 LCD Display 3 MODE HOLD button 4 CAL RECALL button 5 ON OFF button 6 Electrode Collar 7 Electrode Note The Electrode cap is not shown Display Description 1 Reading 2 Units 3...

Page 6: ...Hold Press the MODE HOLD button to freeze the current reading The HOLD display icon will appear along with the held reading The held reading will be stored in the next 15 reading storage location Pre...

Page 7: ...epeat step 1 to store the next reading 4 If an attempt is made to store more than 15 readings the stored readings starting with the first reading will be overwritten Recalling Stored Readings NOTE Fir...

Page 8: ...tore vertically Battery Replacement 1 Twist off the battery compartment cap 2 Hold the battery housing in place with one finger Remove the battery carrier by pulling on the small tabs 3 Replace the fo...

Page 9: ...r and stir bars Display frozen HOLD function Press MODE or turn meter off Button response Remove batteries stored data will be lost Steady 1 display Wait Reading not stable yet Replacing the Electrode...

Page 10: ...of one 1 year from the original purchase date The probe is guaranteed to be free from defects in material and workmanship for a period of six 6 months from the original purchase date In the event that...

Page 11: ...LaMotte Company will service and repair out of warranty products at a nominal charge...

Page 12: ...aMOTTE COMPANY Helping People Solve Analytical Challenges PO Box 329 Chestertown Maryland 21620 USA 800 344 3100 410 778 3100 Outside U S A Fax 410 778 6394 Visit us on the web at www lamotte com 5 08...

Reviews: