background image

Page

   

9

www.howdens.com

Mains lead

Socket on the ceiling 

16 of 48

Mains lead

Socket on the ceiling 

16 of 48

7.

 Place the inner and outer chimneys on the 

extractor hood, and make the electrical connection.

8. 

Fix the extractor assembly to the upper plate 

with 16 screws.

2 of 6

2 of 6

9.

 Connect the duct to the outlet on the ceiling if 

ducting out, or to the filter if recirculating.

Upper 2 holes 

 

(82.8 to 102.7cm)

2 of 6

Lower 2 holes    

 (62.7 to 80.3cm) 

Summary of Contents for LAM2600

Page 1: ...Stainless Steel Glass Island Extractor LAM2600 Instillation User Instructions issuF VMZ...

Page 2: ...rmation 5 Methods of Extraction 6 Installation 7 Electrical Connections 11 Operating Your Extractor 12 The Grease Filters The Carbon filters Maintenance 13 General Cleaning Replacing the halogen Lamps...

Page 3: ...ates that this appli ance may not be treated as household waste Instead it shall be handed over to the applicable collection point for recycling of electrical and electronic equipment Disposal must be...

Page 4: ...sell the extractor please remember to pass on the instruction book to the new owner Technical Information The extractor is designed to give you the option to extract air by ducting to the outside and...

Page 5: ...ss canopy a telescopic decorative outer chimney adjustable inner chimney assembly a ducting connector and a bag of fixings and screws Upper chimney Extractor hood Ducting connector 150mm diameter Duct...

Page 6: ...arged into a flue which is used for exhausting fumes from appliances supplied with energy other than electricity 3 Ensure the requirements of the local authorities are adhered to concerning the discha...

Page 7: ...shown and install the ducting facilities if ducting the extractor out in the ceiling Ensure that the extractor is secured into joists it may be necessary to add wooden struts between the joists 188 2...

Page 8: ...inimum allowable clearance is 700mm 188 259 H min 62 7cm max 102 7cm 75cm recommended worktop 70cm minimum 32 of 48 4 Place the exhaust duct onto the connector and secure it with duct tape or tie wrap...

Page 9: ...the inner and outer chimneys on the extractorhood andmaketheelectricalconnection 8 Fix the extractor assembly to the upper plate with 16 screws 2 of 6 9 Connect the duct to the outlet on the ceiling...

Page 10: ...Page 10 www howdens com 2 of 6 2 of 6 11 Finally fix the outer chimney to the extractor hood with 2 screws 2 of 6 2 of 6 10 Slide up the inner chimney and fix it to the upper plate with 2 screws...

Page 11: ...ans that both the live and neutral supplies are switched and disconnected at the same time The terminations labelled SUPPLY are for the connection for the internal house wiring and the terminations la...

Page 12: ...to use the extractor without the grease filter since grease build up could prevent the motor working properly If the filter is not cleaned regularly the risk of fire will be increased The Carbon Filte...

Page 13: ...ERVED If the power supply is cut or damaged in any way disconnect the extractor from the electricity supply and call the service number on the rear cover of this booklet General Cleaning Wipe the exte...

Page 14: ...clean check carbon filters if fitted If they have not been replaced for more than six months remove and insert new ones As time goes by accumulated grease tends to stifle the carbon filters in just th...

Page 15: ...nd operated in accordance with the manufacturer s instructions and used for normal domestic purposes This guarantee does not cover accidental damage misuse or alterations which are likely to affect th...

Reviews: