Support screws

10mm out of the wall

650 mm Minimum distance 

*750 mm Recommended distance

Worktop

Wall

200mm

60mm

65mm

mm

A

B

B

A

www.howdens.com

Page _ 10

LAMONA 

Appliances

Hanging your extractor               

  

This instruction must be strictly adhered to. Failure to comply could result in overheating and  

 

serious damage to your appliance. It is recommended that the installation is carried out by two people.

Before drilling or chiselling the ceiling or wall, check for pipes and power cables.

Ensure extractor is installed level above the worktop.

• 

If ducting externally ensure the ducting tube is kept as short as possible and with the minimum 

of bends to permit the smoothest 

 (Maximum length 3 metres.). Ducted air must not be 

discharged into a 

 which is used for exhausting fumes from appliances supplied with energy other 

than electricity. (E.g. gas boilers)

• 

Ensure the requirements of the local authorities are adhered to concerning the discharge of exhaust 

air.

• 

Ensure adequate room ventilation is provided when the extractor is used in the same room as 

appliances supplied with energy other than electricity.

• 

Never duct into a hot air 

 such as a central heating duct

1.  Remove the grease 

 before trying to install.

2.  The recommended 

 height for the hood is 750mm above the worktop. This can be reduced to a 

minimum of 650mm if required.

3.  Mark and drill the holes required to mount the extractor body. 

4.  The principal securing point is               is the two upper screws, secure in position but not fully flush.

bracket

 

5.  With the help of an assistant, hang the extractor body on the upper screws and secure in position 

through the lower two mounting screws.

Summary of Contents for LAM2410

Page 1: ...Instructions and Installation LAM2410 Stainless Steel LAM2411 Black 60cm Chimney Extractor www howdens com appliance registration...

Page 2: ...See back page for product serial number...

Page 3: ...on many factors including the ambient temperature in the kitchen the related ambient temperature of the metal surfaces the general ventilation within the kitchen the type of food being cooked and the...

Page 4: ...a r t x E Control panel layout Care and maintenance General cleaning Grease filters Carbon filters Replacing the lamps Installation Methods of extraction Extraction via ducting Extraction via recircul...

Page 5: ...or drugs Product must be disconnected from the mains during installation maintenance cleaning and repair procedures Repair procedures must always be performed by service agents The manufacturer shall...

Page 6: ...Vent 3 Lower Chimney Section 4 Fan and Light Controls 5 Extractor Body 6 Grease Filters 7 Light General Information Operation Extractor layout Control panel layout 1 Extractor Power Off 2 Extractor P...

Page 7: ...er General cleaning Wipe the external surfaces of the appliance regularly using warm water and a mild detergent NEVER use abrasive cleaners or strong household cleaners as they may affect the appearan...

Page 8: ...uctionwillbe lowerwheninstalledinrecirculationmode thisisnormalandnotaproductfault Replacing the lamps The lamps on this model are service fix only and replacement should be carried out by an authoris...

Page 9: ...lation in the room when the extractor is used at the same time as an appliance burning gas or other fuels Connect the external ducting kit to the outlet of the extractor Charcoal filters are not requi...

Page 10: ...telescopic decorative chimney a bag of wall and screws two brackets a ducting connector and reducer 1 3 2 4 5 6 7 8 9 10 1 Main Extractor Body 2 Cable Grid 3 Upper Chimney 4 Lower Chimney 5 Outlet Red...

Page 11: ...ischarged into a which is used for exhausting fumes from appliances supplied with energy other than electricity E g gas boilers Ensure the requirements of the local authorities are adhered to concerni...

Page 12: ...ernally 4 Rest the chimney sections on the main extractor body and extend the upper section to the ceiling 5 Use the extended chimney sections to mark up the appropriate position of brackets 4 and 5 6...

Page 13: ...s are switched and disconnected at the same time The terminations labelled SUPPLY are the connections for the internal house wiring and the terminations labelled LOAD are for connection to the applian...

Page 14: ...MATION General Total power consumption 67 5W Fuse 3 A Voltage Frequency 220 240 V 50 Hz Cable type section 0 75mm 3 core or equivalent Cable length max 1 5m Lamps 1 x 2 5W LED warm white 3000k TROUBLE...

Page 15: ...urer s instructions and used for normal domestic purposes This guarantee does not cover accidental damage misuse or alterations which are likely to affect the product The guarantee is invalid if the p...

Page 16: ...Product serial number Place sticker here ISSUE v1 010618...

Reviews: