background image

Exclusive to Howdens Joinery.co

Page _  13

User manual LAM2403

TROUBLESHOOTING GUIDE
Symptoms

Possible Cause

Solutions

Lamps fail to operate?

• 

A replacement lamp is probably 

necessary, but first check that the 

lamp is correctly fitted into its holder.

(Remember that the lamps are not               

covered by the guarantee.)

Disconnect the mains electricity supply before adjusting 

or replacing the lamps.  

The extractor lamps may become hot; therefore ensure 

the bulb has cooled sufficiently before replacing.

• 

Power is cut. 

Check if there is power. Check the fuses in the fuse box. If 

necessary, replace or reset the fuses.

Motor is on but fan does 

not seem to be as efficient 

as usual?

• 

Clogged filters can reduce the 

product’s efficiency. Check the grease 

and charcoal filters (if fitted) also 

ensure any venting is not obstructed?

Clean the grease filters with warm water and mild 

detergent, and/or replace any charcoal filters 

The extractor works normaly 

but smells linger?

• 

Clogged filters can reduce the 

product’s efficiency and may cause 

unwanted smells. 

Clean the grease filters with warm water and mild 

detergent, and/or replace any charcoal filters.

Product does not operate?

• 

The mains fuse maybe defective or 

has tripped

Check fuses in the fuse box. If necessary, replace or 

reset them.

• 

Product is not connected properly.

 Check all power connections.

If you cannot eliminate the problem after following the instructions in this section, consult your 

depot or the Authorized Service Agent. Never try to repair a nonfunctional product yourself.

Troubleshooting

Technical specification

TECHNICAL INFORMATION
General

Total power consumption

350W

Fuse

3 A

Voltage /Frequency

220-240 V ~ 50 Hz

Cable type / section

0.75mm², 2 core or equivalent

Lamps 

E14 40W each

Summary of Contents for LAM2403

Page 1: ...User Installation Guide LAM2403 Stainless Steel Chimney Extractor...

Page 2: ...ful tips about usage Warning for possible hazards to health and property Warning possibility of electric shock This product s packaging material is recyclable Help recycle it and protect the environme...

Page 3: ...Extractor layout 04 Control panel layout 04 Care and maintenance 05 General Cleaning 05 Grease Filters 05 Carbon Filters 05 Replacing the Lamps 06 Installation 07 Methods of extraction 07 Extraction...

Page 4: ...red by the use of alcohol and or drugs Product must be disconnected from the mains during installation maintenance cleaning and repair procedures Repair procedures must always be performed by qualifie...

Page 5: ...chimney section 4 Fan and light controls 5 Extractor body 6 Grease filters 7 Light General Information Operation 4 0 1 2 4 5 6 7 8 2 3 4 5 1 Extractor layout Control panel layout 1 Light on off 2 Ext...

Page 6: ...surfaces of the appliance regularly using warm water and a mild detergent NEVER use abrasive cleaners Care and maintenance The Grease Filters The grease filter is of a metallic material and should be...

Page 7: ...itched off and the lamps have had time to cool Remove the grease filters to gain access Unscrew the lamps and replace with new lamps of the same type and wattage Lamp replacement is not covered by you...

Page 8: ...tside are already operating unless perfect ventilation can be guaranteed Connect the external ducting kit to the outlet of the extractor Charcoal filters are not required if the extractor is to be duc...

Page 9: ...body a two piece telescopic decorative chimney two fixing brackets and ducting connector and reducer 1 Main Extractor Body 2 Upper Chimney 3 Lower Chimney 4 Vent Adaptor 5 Vent outlet Reducer 6 Upper...

Page 10: ...te room ventilation is provided when the extractor is used in the same room as appliances supplied with energy other than electricity Never duct into a hot air flow such as a central heating duct We s...

Page 11: ...venting externally Rest the chimney sections on the main extractor body and secure in position with bracket 7 Next extend the upper section to the ceiling and mark up the position for the upper fixing...

Page 12: ...The terminations labelled SUPPLY are the connections for the internal house wiring and the terminations labelled LOAD are for connection to the appliance IMPORTANT The wires in the mains lead are col...

Page 13: ...also ensure any venting is not obstructed Clean the grease filters with warm water and mild detergent and or replace any charcoal filters The extractor works normaly but smells linger Clogged filters...

Page 14: ...y installed and operated in accordance with the manufacturer s instructions and used for normal domestic purposes This guarantee does not cover accidental damage misuse or alternations which are likel...

Page 15: ...Exclusive to Howdens Joinery co Page _ 15 User manual LAM2403 Notes...

Page 16: ...If supplied please stick your self adhesive product rating plate here or make a note of the product serial number below in the box below for future reference Serial Number...

Reviews: