Page _ 10
LAMONA
Appliances
Hanging Your Extractor
This instruction must be strictly adhered to. Failure to comply could result in overheating and
serious damage to your appliance. It is recommended that the installation is carried out by two people.
Before drilling or chiselling the ceiling or wall, check for pipes and power cables.
•
If ducting externally ensure the ducting tube is kept as short as possible and with the minimum
of bends to permit the smoothest airflow. (Maximum length 3 metres.). Ducted air must not be
discharged into a flue, which is used for exhausting fumes from appliances supplied with energy other
than electricity. (E.g. gas boilers)
•
Ensure the requirements of the local authorities are adhered to concerning the discharge of exhaust
air.
•
Ensure adequate room ventilation is provided when the extractor is used in the same room as
appliances supplied with energy other than electricity.
•
Never duct into a hot air flow such as a central heating duct
We strongly advise that all exterior outlets be fitted with a non return flap or louvred slatting.
•
Remove the grease filters before trying
to install.
•
The recommended fixing height for the
hood is 750mm above the worktop.
This can be reduced to a minimum of
700mm if required.
•
Mark and drill the holes required to
mount the extractor body.
•
The principal securing point is the top
keyhole slot; fix this screw first leaving
approximately 5mm between the screw
head and the wall.
•
With the help of an assistant, level and
secure in position through the lower
two holes tightening the upper screws
as necessary.
75
130
150
244
400
Y
137
550
(**)
Please use rawl plugs and
screws appropriate to the type of
wall.
700 mm Minimum distance to worktop
750 mm Recommended distance to worktop
10.**
10.**
10.**
10.**
10.**
10.**
8.
8.
8.
8.
9.
9.
6.
7.
8.
9.
9.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
2.
3.
4.
5.
1.
1.
3.
5.
4.
6.
2.
7.
Ducting kit
Supplied Separately
Vent through external
wall or ceiling
Filtered air
recirculated
1
2