16
www.howdens.com
Installation Instructions
Electrical connection
(continued)
N
L
L
N
LOAD
SUPPLY
LOAD
SUPPLY
DP
13A 250V~
FUSE
ON
Blue
(Neutral)
Brown
(Live)
Green & Yellow
(Earth)
IMPORTANT:
The wires in the mains power cable
are
coloured in accordance with this code:
As the colours of the wires in the mains lead of
this appliance may not correspond with the coloured
markings identifying the terminals in your spur box,
proceed as follows:
Terminology
•
Connections labelled SUPPLY pertain to the internal
house wiring.
•
Connections labelled LOAD are for linking to the
appliance.
The blue wire
must be connected to the terminal
which is marked with the letter
‘N’
or coloured
BLACK
The brown wire
must be connected to the terminal
marked with the letter
‘L’
or coloured
RED
The green and Yellow wire
must be connected to the
terminal which is marked with the letter
‘E’
or symbol.
Ensure live connections are safely insulated.
Double Pole:
The term DOUBLE POLE -/+ indicates that both the live and neutral supplies are
switched and disconnected simultaneously.
i
Blue -
Neutral
Brown -
Live
Green / Yellow -
Earth
The
earth
wire must be
sufficiently long
enough so that
if the strain
relief fails; the
'
live
' wires of
the cable are
subjected to
tension before
the earth wire.
Crimp.
This induction
hob has been
fitted with a
temperature
resistant
mains power
cable.
This appliance
MUST be earthed.