![Lamona LAM1500 User Manual Download Page 18](http://html.mh-extra.com/html/lamona/lam1500/lam1500_user-manual_671698018.webp)
Gas connection
These instructions are for qualifi ed personnel,
installation of equipment must be in line with
relevant national standard.
(For U.K only: by
law the gas installation must be carried
out by a “Gas Safe” installer).
All work must be carried out with the electricity
supply disconnected.
The rating plate on the hob shows the type
of gas with which is it designed to be used.
Connection to the mains gas supply or gas
cylinder should be carried out after having
checked that is regulated for the type of gas with
which it is supplied. If it is not correctly regulated
see the instructions in the following paragraphs
to change gas setting.
For liquid gas (cylinder gas) use pressure
regulators which comply with the relevant
national standards.
Use only pipes, washers and sealing washers
which comply with relevant national standards.
For some models a conic link is supplied for
the installation in the countries where this
type of this link is obligatory: in the image
below it is pointed out how to recognise the
different of links (CY= cylindrical, CO= conic). In
every case the cylindrical part of the link has to
be connected to the hob.
When connecting the hob to the gas supply
using semi-rigid hoses please ensure that the
maximum distance covered by the hose does
not exceed two metres.
Cylindrical
Conical
Adapting the hob to different
types of gas
To adapt the Hob for use with different types of gas,
1. Flame failure device
2. Spark plug
3. Injector
4. Burner
carry out the following instructions:
Unscrew the injector and replace it with one
suitable for the gas to be used.
•
Remove the grids and burners.
•
Insert an hexagonal spanner (7mm) into the
burner support.
•
Unscrew the injector and replace it with one
suitable for the gas to be used, see page 20.
NOTICE
If the gas type of the unit is changed, then the rating
*Depends upon model type
plate that shows the gas type of the unit must also
be changed.
User manual LAM1500