05 - Installation
General information
Installation should only be carried out by a qualifi ed
installer or engineer.
Please Note:
Although every care has been taken to ensure
this appliance has no burrs, or sharp edges, We
recommend that you wear protective gloves when
installing and moving this appliance. This will
prevent injury.
The hob should not be fi tted above a washing
machine, dishwasher, a fridge or a freezer. Wall
surfaces above the work surface and in the
immediate vicinity of the cooking hob must be heat
resistant.
Laminated surfaces and the adhesive used for
fi xing them must be heat resistant in order to avoid
any damage.
Installations should be carried out in line with the
National Regulations applicable with this product
type.
Room ventilation
The air for combustion is taken from the room air
and the exhaust gases are emitted directly into the
room.
Good room ventilation is essential for safe operation
of your appliance. If there is no window or door
available for room ventilation, an extra ventilation
must be installed.
Do not install this appliance in a room below ground
level unless it is open to ground level on at least
one side.
Failure to install correctly is dangerous and could
result in prosecution.
Protecting the hob cut out
The types of chipboard used for work surfaces
swell relatively quickly in contact with humidity.
Apply a special varnish or adhesive to the cut
edges to seal and protect it from moisture ingress.
Positioning
The hob is designed
70mm
60mm
from the hob
50mm
480-490mm
to be built into a worktop as
detailed in the image above.
Aperature width - 480 - 490mm x 560mm
The hob may be installed in any worktop which is
heat resistant to a temperature of 100°c, and has
a cut thickness of 20-45mm. The dimensions of the
insert to be cut out of the worktop.
If the hob is fi tted next to a cabinet on either side,
the distance between the hob and cabinet must be
at least 110mm, while the distance between the
hob and the rear wall must be at least 60mm.
When there is an accessible space between the
built in hob and the cavity below, a dividing panel
made of insulating material should be inserted
(wood or a simular material).
User manual LAM1500
_ 14
560mm
110mm
Room size
Ventilation opening
smaller than 5 m
3
min. 100 cm
2
5 m
3
to 10 m
3
min. 50 cm
2
greater than 10 m
3
not required
In the cellar or
basement
min. 65 cm
2