Should the appliance be pre-set for a different type
of gas than that available, proceed as follows:
• Replace the injectors ‘B’ with the injectors of a
size corresponding to the type of gas to be used (see
table “Burner Characteristics / Injector Table”).
B
Minimum rate adjustment
1. Ignite the burner that is to be adjusted and turn
the knob to the reduced position.
2. Remove the knob from the gas tap.
3. Use an appropriately sized screwdriver to adjust
the flow rate adjustment screw which will be either
inside or adjecent to the gas tap shaft. The normal
length of a straight flame in the reduced position
should be 6-7 mm.
For LPG (Butane - Propane) turn the screw fully
clockwise.
4. If the flame is higher than the desired position,
turn the screw clockwise. If it is smaller turn anti
clockwise.
5. Check that the burner flames are stable at both
to high and reduced positions.
NOTICE
If the gas type of the unit is changed, then the
rating plate that shows the gas type of the unit must
also be changed.