background image

 

TAP6000-2, TAP6002-2 & TAP6004-2 
Arroscia 3 in 1 Hot Water Tap  

 

 

02-20

 

Guarantee (UK only): 

 

Your tap has the benefit of a comprehensive manufacturer’s guarantee, details of which are shown on your Proof of Purchase 
Document. Any claim during the period of the guarantee must be accompanied by the Proof of Purchase. The product must be 
correctly installed and operated in accordance with the manufacturer’s instructions and used for normal domestic purposes. This 
guarantee does not cover accidental damage, misuse or alterations which are likely to affect the product. The guarantee is invalid if the 
product is tampered with, or repaired by any unauthorized person. The guarantee in no way affects your statutory or legal rights. 

 

Care Instructions for your Kitchen Sink Mixer: 

 

To maintain the appearance of this tap, ensure that it is regularly cleaned only using a clean, soft damp cloth. A solution of warm water 
and a mild liquid detergent may be used where necessary, and then the fitting rinsed thoroughly and wiped dry. Any other cleaning 
action will invalidate your warranty.  

 

Abrasive cleaners, scouring cleaners and acidic cleaners 

must not be used 

under any circumstances. Avoid contact with all solvents 

(including chlorinated solvents, ketones or acetones as these may result in surface deterioration or etching). Also avoid contact with 
any harsh household chemicals such as oven cleaners, drain cleaners, rust removers, paint strippers and toilet bowl cleaners, bar 
keepers friend or Brasso. 

 

Where the tap has a removable aerator on the spout exit it can be removed and cleaned periodically to maintain optimum flow 
performance. 

Important Technical Data: 

 

Minimum operating pressure (hot): 0.75 bar 

 

Minimum operating pressure (cold): 1.5 bar 

Maximum operating pressure: 5.5 bar* 

 

Maximum domestic hot water temperature:  70°C* 

 

Flow characteristics: Domestic Hot & Cold share 
outer single flow spout. 
Boiled water: Through centre spout channel. 

 

 
Recommended domestic hot water temperature:  46°C 

 

*If these temperatures or pressures are exceeded, even for short periods, damage can result. In these instances a thermostatic mixing 
or pressure reducing valve should be installed. 

 

This product is manufactured in accordance with recognised European standards. Please ensure that your kitchen mixer is fitted in 
accordance with Local Water Byelaws. 

Where hot and cold water mix within the tap, then suitable non return (check) valves 

should be installed to both the hot and cold supplies to prevent backflow

, a preinstalled non return valve on the cold supply flexi 

hose (B6) is already supplied (see instructions key). 

 

Hot and cold supply pressures should be as closely balanced as possible for best results. Supply pipes should maintain the maximum 
diameter until immediately before the fitting. The differential between the hot and cold water supply temperatures should be sufficient to 
allow correct mixing function. 

 

These installation guidelines have been prepared for your direction and you must exercise due care at all times. We do not accept 
responsibility for problems that may occur through improper installation. Whilst assembling the tap take care not to accidentally loosen 
any factory fixed assemblies. 

 

This tap has been 100% assembly tested; therefore you may expect a small residual amount of water to remain in the tap when 
delivered. Any water marks can be removed using the above care advice. 

 

Installation Preparation 

 

⚠ 

Before installing the new mixer it is essential that you thoroughly flush through the supply pipes in order to remove any 

remaining solder, swarf or impurities from your system. Failure to carry out this simple procedure could cause problems or 
damage to the workings of the mixertap or boiler. 

 

We recommend installing particle filters (not shown) and isolation valves (B5) to both the hot and cold feed pipes in an 
accessible position. This will help to prevent premature failure of the valves and ease any future maintenance. 

 

Ensure you have suitable domestic hot and cold water pressure before installing this product (see technical data 

for more 

information). 

 

All parts should be removed from their packaging and inspected for any transport damage and that all parts are present prior to 
installation. 

 

Shut off your water heating system and ensure that your mains stopcock is closed. Open the lowest hot and cold taps in the house and 
allow the water to run until fully stopped. 

 

If replacing an existing tap, remove the tap & clean the end of the feed pipes using wire wool, the tap hole area should be 

free from 

dirt and sealant. Loosely position the tap and tail pipes to check if any alteration to the existing pipework is required, if this 
is the case do this now. 

Summary of Contents for Arroscia TAP6000-2

Page 1: ...Please ensure that your kitchen mixer is fitted in accordance with Local Water Byelaws Where hot and cold water mix within the tap then suitable non return check valves should be installed to both the hot and cold supplies to prevent backflow a preinstalled non return valve on the cold supply flexi hose B6 is already supplied see instructions key Hot and cold supply pressures should be as closely ...

Page 2: ...ed blue banded flexible hose M10 x BSPM 15mm 1 B7 Non return valve factory fitted into flexible hose B6 1 C1 Cold out from tap to filter flexible hose M8 x 3 8 F includes captive seal 1 C2 3 8 M x F brass adaptor 1 C3 NPT M x pushfit 1 C4 outside diameter plastic pipe 1 C5 Filter bracket screw 1 C6 Filter bracket 1 C7 Filter cartridge 1 C8 outside diameter plastic pipe cut from C4 1 D1 Steaming ho...

Page 3: ...horseshoe A7 over the fixing stud A8 Note only if the tap is to be fitted to a stainless steel sink then the white triangular plate A5 can be fitted where shown to improve the stability of the tap 9 Using a 13mm box spanner or small adjustable spanner tighten fixing nut A9 onto the fixing stud A8 10 Screw pushfit C3 into brass adaptor C2 We recommend using PTFE tape do not use sealing compound on ...

Page 4: ...issipate with flushing whilst harmless to consume if the carbon particles are not flushed prior to connection to the boiler they may partly block the boiler and reduce the flow rate You must flush the filter for at least 2 litres with cold water or until the water become clear without black carbon particles 3 Place the pipe C4 from the filter cartridge C5 outlet into a bowl or bucket 4 Turn on the...

Reviews: