background image

Cleaning and user maintenance shall not be made by children without supervision.

The refrigerant in this unit with a fluorinated greenhouse gas covered by the Kyoto 

Protocol, which dangerous for the environment and for the global warming if it is 

enters into atmosphere.

Chemical name of refrigerant (R-134a) is a fluorinated greenhouse gas covered by the 

Kyoto Protocol, Its global warming potential(GWP) is the 1430.

d)

e)

The ambient temperature operating range is between 5

 and 35

 with a relative

humidity ranging from 30% to 80%. For maximum efficiency use the unit between 15

and 32

.

SPECIFICATIONS

04

03

When using electrical appliances, basic safety precautions should always be 

followed including the following:

 If the machine`s power supply cord is damaged, you must entrust the 

manufacturers of the machine. Maintenance service center or qualified 

technicians will change for you, in case of any danger.

Leave the appliance to stand for at least two hours before power on, especially after

transportation.

Make sure that the voltage matching with the relevant data indicated on the rating 

label.

The socket must be with grounding.

Keep the appliance dry. Make sure no water on the top or the body.

Do not unpin the plug when the appliance is working.

If moving needed, please switch it off and unpin the plug.

Allow a free space of 15 cm around air inlet of the appliance.

Do not insert any object into the air inlet or outlet openings.

Do not place the dehumidifier near a heating source (esp. a radiator) or indirect 

sunlight.

Ensure that the appliance does not become hot.

Empty the water tank regularly. (In extreme conditions the water tank may be full 

after a few hours operation.)  Clean the air inlet filter if it becomes contaminated: the 

appliance is most effective when

the filter is clean.

Please do not expect the air dehumidifier to be effective when too many doors or 

windows are opened or when something in the room is producing a lot of humidity.

The air dehumidifier will come into effect immediately. However, the reduction of 

humidity many hardly be measureable during the first few days.

If the supply cord is damaged, it must be replaced by the manufacturer, its servuce 

agent

or similarly qualified persons in order to avoid a hazard.

This appliance can be used by children aged from 8 years and above and persons 

with reduced physical, sensory or mental capabilities or lack of experience and 

konwledge if they have beeen given supervision or instruction concerning use of the 

appliance in a safe way and understand the hazards involved.

Children shall not play with the appliance.

Cleaning and user maintenance shall not be made by children without supervision.

a)

b)

c)

IMPORTANT SAFEGUARDS

Rated freguency:
Max power input:
Rated input power:
Tank capacity:
Air volume:
Noise level:
Refrigerant:
Net weight:
Suction pressure:

Discharge pressure:

Saluber PD23E-20

20 L/Day(30

RH80%)

9.5 L/Day(26.7

 RH60%)

AC 220-240V

50 Hz
370W
240W

4 L

180m³/h

42 dB(A)

R134a /160g

14.3kg

0.5MPa

1.5MPa

Model No.:

Dehumidify capacity:

Rated voltage:

Summary of Contents for Saluber PD23E-20

Page 1: ...MANUAL DEHUMIDIFIER Saluber PD23E 20 Thanks for choosing this dehumidifier before using Please read this manual carefully and follow this manual strictly Please keep it properly after reading for future reference ...

Page 2: ... CLEANING FAULT CODE 03 04 05 06 07 08 08 08 10 12 OTHER NOTICE 09 TROUBLE SHOOTING 13 02 DEHUMIDIFIER Saluber PD23E 20 01 To prevent damage and voiding your warranty Please place the unit in its right position for a minimum of two hours before operating For best result from your portable dehumidifier please read this instruction manual carefully and save it for future refer ence IMPORTANT NOTICE ...

Page 3: ...et or outlet openings Do not place the dehumidifier near a heating source esp a radiator or indirect sunlight Ensure that the appliance does not become hot Empty the water tank regularly In extreme conditions the water tank may be full after a few hours operation Clean the air inlet filter if it becomes contaminated the appliance is most effective when the filter is clean Please do not expect the ...

Page 4: ...liance will go AUTO function the first time it is switched on and remains in this mode until other type of programming is chosen Depending o n yo u r r e l a t i ve humidity conditions turn the fan speed switch to high or low FAN Ventilation Key FAN Ventilation Key press MODE key to select FAN and FAN indicator light comes on LAMP Start the appliance the lamp will turn on automatically The lamp co...

Page 5: ... position after wiping it off from any water residue EMPTYING THE WATER TANK CONTINUOUS DRAINAGE OPERATION REPLACEMENT AND MAINTENANCE OF AIR FILTER 07 HUMIDITY SETTING Press UP DOWN key to select the desired relative humidity level default relative humidity is 55 Relative humidity 35 is selected the compressor will not stop until water tank full TIMER timer function press timer to program time an...

Page 6: ...roduce a small portion of the heat the room temperature will be a little higher this is a normal phenomenon please feel at ease 4 automatically stop running please send the water in the water drained and put back to the water tank the machine will continue to operate 5 In order to ensure the normal operation do not open the water tank float cover or place any foreign body in the water tank 6 When ...

Page 7: ... the hot water or alcohol gasoline toluene and other dangerous flammable liquid Power failure or long term nouse please unplug the power cable plug so as to avoid leakage and fire Around the body or out of the air outlet do not put items to ensure that the effect of the desiccant air When not in use please put in the position of ventilation and unplug the power plug to avoid danger After filtering...

Page 8: ...laced in the right position 2 Is the power plug inserted right position 3 Is the fuse broken 4 Is the power off The dehumidification amount is too low 1 Is the front filter net dirty 2 Is the interior temperature and the humidity too low 3 Is the air outlet and air inlet jammed Long time operation can not reach the suitable humidity condition 1 Does the door or window too widely open 2 Is there an...

Page 9: ......

Reviews: