4  USE 

CAUTION!!! - ONLY USE OUTDOORS

 

 

This product was designed and tested for outdoor use alone. Indoor installations are not allowed; 

 

Safely position the hot spot so that it cannot be accidentally hit 

 

Position the hot spot as horizontally as possible 

 Do not use the unit as an incinerator or in any other way other than that for which it was designed; 

 No other fuel besides wood pellets must be used; 

 Do not use liquid fuels; 

 When the stove is turned on, it can reach extremely high temperatures to the touch, especially its outer 

surfaces. Operate carefully to avoid burns; 

 Do not make any unauthorised modifications to the device; 

 Only use original replacement parts recommended by the manufacturer; 

 Make sure that all exhaust system joints are hermetically sealed with silicone, are resistant to heat (250 

°C) and are not damaged. 

CAUTION

: keep all flammable products well away from the product when it is operating (MINIMUM: 100 

cm from the front wall). 

CAUTION

: to prevent the escape of fumes, the combustion chamber must be kept closed except during 

cleaning operations, to be carried out when the product is off. 

CAUTION

: in the event of pellet supply when the product is on, make sure that pellets are not finished and 

that the flame is always present and live in the brazier. 
Do not refill the tank if you notice that the pellet is ending and the flame is absent or low. 

Failure to comply with this indication can be dangerous and cause fume malfunction and their 

explosion 
CAUTION

 prevent the fuel bag to come into contact with hot surfaces. 

CAUTION

: remove any residue of unburned pellets caused by failed ignitions before starting the hot spot 

again 

CAUTION

: if during the ignition phase, the product does not start and you notice a lot of smoke in the 

combustion chamber, immediately turn off the stove and replace the pellets being used, as these may be 
too high in moisture. Forcing ignition could make your product a hazard. 

CAUTION

: if during cleaning, you find traces of spongy or hard (though not ash) pellets, replace the pellets 

being used, as this residue may come from scraps of low quality sawdust not usable in this type of product. 
Forcing ignition can cause a fire or lots of smoke. 

CAUTION

: monitor proper combustion of the pellets in the brazier. Should you detect accumulations of 

unburned pellets, IMMEDIATELY TURN OFF the product and contact the service centre. 

CAUTION

: pay the utmost attention in the presence of children. 

Summary of Contents for IDRO Hot Spot 13

Page 1: ...fully read the instructions and information before use Dear customer thank you for choosing one of our products which is the result of technological expertise and our continuous quest for superior pro...

Page 2: ...operate the hot spot with regulation wood pellets refer to the FUEL chapter Never use liquid fuels to operate the product and to stoke the embers present Discontinue use of the product in the event of...

Page 3: ...ling up the tank 10 4 3 Ignition 11 4 4 Combustion mode 11 4 5 Brazier cleaning 12 4 6 Shutdown 12 5 WARNINGS AND MAINTENANCE 13 5 1 Opening the door 13 5 2 Disposal of ashes 13 5 3 Brazier cleaning 1...

Page 4: ...3 kW Hourly consumption min max 1 5 2 5 Kg h Pellet tank capacity 13 Kg Weight 90 Kg Dimensions LxPxH 546x520x2118 mm 1 3 Product identification data data label The technical label shows device data a...

Page 5: ...dusty and with regular length LOW QUALITY pellets are of varied lengths dusty with vertical and horizontal splits Since pellet characteristics and quality greatly influence the autonomy efficiency and...

Page 6: ...and slide it to the bottom Fig 3 3 Place the support plate and the lower dish over the pipes then secure everything with the supplied wing nuts Fig 4 4 Lay the three support and the upper dish then s...

Page 7: ...en moving the package move with slow and continuous movements to avoid tearing the ropes chains etc Do not tilt excessively in order to avoid overturning Do not stand within range of the loading unloa...

Page 8: ...n the event of pellet supply when the product is on make sure that pellets are not finished and that the flame is always present and live in the brazier Do not refill the tank if you notice that the p...

Page 9: ...9 PELLET LOADING DOOR 4 1 Instructions for use AIR ADJUSTMENT BRAZIER SHAKER COMBUSTION CHAMBER DOOR...

Page 10: ...the lid B by turning the knob towards the open position fig 10 Raise the lid B and put pellet in the tank fig 11 Lower the lid B and move the handle towards the closed position fig 18 The pellets can...

Page 11: ...es a minimum height of about 7 cm so as to lick the holes located in the rear wall The hot spot is now on CAUTION always clean the brazier prior to each ignition to avoid false starts and production o...

Page 12: ...ig 17 the fall of the pellets into the brazier will stop Combustion will continue for about 20 minutes after which the machine will switch off To switch the hot spot back on move the lever to position...

Page 13: ...y black smoke it may mean that there are ash deposits or incrustations which are not allowing correct hot spot operation and which must be removed To perform periodical cleaning remove the brazier by...

Page 14: ...uld slow down or block the pellets falling into the brazier Fig 20 Fig 21 CAUTION RISK OF BURNS CAUTION Perform this operation when the hot spot is cold 5 8 Cleaning the glass part of the door The doo...

Page 15: ...cladding once a year Leave the door half open so as to prevent any condensate inside the combustion chamber 5 11 Routine and special maintenance These operations must be scheduled YEARLY with a Techni...

Page 16: ...Laminox S r l Divisione Idro Zona Industriale Callarella 261 263 62028 SARNANO MC Italy Tel 39 0733 657 622 Fax 39 0733 657 494 www laminox com e mail idro laminox com rev 2 0 2018 EN...

Reviews: