background image

X:\PmDoku\Geräte\Synmet NAV\englisch\SYNMET MANUALE 1.doc
STW Manual

Page 12 of 25

Figure: Front panel SYNMET

Figure: circuit diagram of data cable (connection of Sub-D-connectors)

Summary of Contents for SYNMET-IND Series

Page 1: ...X PmDoku Geräte Synmet NAV englisch SYNMET MANUALE 1 doc Release 31 99 31 LAMBRECHT Interface System SYNMET IND STW Manual Setting to work ...

Page 2: ...50 LITE 13 9 0 EVALUATION SOFTWARE METEOWARE PRO 13 10 0 OPTIONS AND ACCESSORIES FOR SYNMET IND 13 10 1 MODEMS 13 10 2 NETWORK SOLUTIONS 15 10 3 KEYBOARD AND DISPLAY UNIT 16 10 3 1 General 16 10 3 2 The LC display 16 10 3 3 The keyboard 16 10 4 PRESSURE SENSOR AND UNINTERRUPTABLE POWER SUPPLY UNIT 18 10 4 1 General remarks 18 10 4 2 Technical Data 18 10 5 POWER DISTRIBUTION BOX 18 11 0 INTERFACE D...

Page 3: ...cation data sheet The SYNMET system is equipped with the below specified components and modules In case of any questions always refer to these specific customer data for a proper identification System abbreviation SYNMET IND SCH 660 Type No 00 95661 __ __ __ __ __ __ Identification digits 1 2 3 4 5 6 Serial Number LAMBRECHT wiring diagram SKF SWF Rev LAMBRECHT Quality Assurance Department Göttinge...

Page 4: ...4 not in use 5 basic configuration 1 RS 232c 1 RS 232c RS 422 display and keypad DAC module 6 basic configuration 1 RS 232c 1 RS 232c RS 422 display and keypad 4 channel serial interface 7 not in use Remark A combination of DAC and 4 channel interface is not possible 3 rd digit Sensor interface board SI 1 basic configuration 2 basic configuration 2 DC DC module 12 24 V DC 3 basic configuration 1 D...

Page 5: ...X PmDoku Geräte Synmet NAV englisch SYNMET MANUALE 1 doc STW Manual Page 5 of 25 1 2 Individual configuration data sheet of the SYNMET system Print out of configuration hardcopy to be inserted by WL QS ...

Page 6: ...ions are part of separate documentation material Last not least the software MeteoWare PRO has to be installed on the computer For an easy installation and operation please refer to the software handbooks where you ll also find the necessary hardware requirements for the computer 3 0 Unpacking When unpacking the boxes please check the completeness of all items according to the packing list Some of...

Page 7: ...t minimum height 6 m All other sensors besides the precipitation gauge e g temperature relative humidity pressure radiation have to be installed on a cross arm 2 m above ground level The precipitation gauge has to be installed on a separate small pole so that its upper edge is 1 2 m above ground level Fix all cables to the mast so that there s no looseness which could lead to malfunctions Fasten t...

Page 8: ...nical specifications before mounting any spare fuse If any cable of the system is longer than 25 meters an overvoltage protection has to be used Please contact the factory for detailed information about overvoltage protection parts Open the terminal box by loosening the philips screw on the right hand side of it Unscrew all necessary cable glands from the cable entries at the bottom part of the SY...

Page 9: ... in its lower right hand edge This wiring plan also indicates the used AWG color code Find this plan as an annex to the manuals All wiring can be done without tools To ease the wiring process all terminal blocks can be removed from their sockets by simply pulling them upwards Push the end slices of each cable into the appropriate green terminal blocks until they are in a secure contact position to...

Page 10: ...io 9 grau gr gray gry 10 weiß ws white wht Figure AWG Cable Code Figure terminal bloc with cables 6 2 Sensors Most sensors have a screw connection some require a fixing by terminal blocks in this case a small screw driver is necessary Refer to the LAMBRECHT wiring diagram for specific information 6 3 Data cables Data cables 4 wires shielded have to be connected in the same way as described in chap...

Page 11: ...n of the delivered SYNMET system some LEDs eventually are disabled LED marking colour located on function remark AC power green power supply board PS AC voltage on standard solar green power supply board PS solar power on option battery charge green power supply board PS battery charge option battery fault red power supply board PS battery error option DC output green power supply board PS DC powe...

Page 12: ...X PmDoku Geräte Synmet NAV englisch SYNMET MANUALE 1 doc STW Manual Page 12 of 25 Figure Front panel SYNMET Figure circuit diagram of data cable connection of Sub D connectors ...

Page 13: ...ITE to reload the saved configuration to the RAM Refer to the separate manual FT 50 LITE for more information The stored configuration file also has to be used after exchanging memory components e g the CPU Board 9 0 Evaluation software MeteoWare PRO Install the LAMBRECHT evaluation software MeteoWare PRO according to the separate software manual When choosing the menu Instantaneous Values for the...

Page 14: ...matically under certain conditions alarm etc Details regarding the installation and the setting to work initial operation of these phone modems are described in separate manuals In most countries LAMBRECHT delivers tested and approved modems together with the system Due to different local telecommunication regulations in some countries modems could require an approval of the local authorities in t...

Page 15: ...tween both locations is necessary The equipment is approved by most of the European authorities According to the restrictions of the local telecommunication authorities various types of modems with different power data and frequencies can be chosen Details have to be negotiated before ordering the equipment Details of their installation and the setting into operation procedures of the radio modems...

Page 16: ...d menus for the function control The contrast regulation is automatically dependent upon the operating temperature operating temperature range of 20 to 70 C 10 3 3 The keyboard has 16 membrane keys Most of the membrane keys have two functions The second function of the key will be activated by pressing Shift and the key simultaneously The Exit key will be activated by pressing key Shift and Exit C...

Page 17: ...aneous values of more parameters you must press any key 2 Automatic change If more than 4 parameters are defined the display change automatically after 15 seconds to show the instantaneous values Additionally it is possible to change the displayed parameters with any key 3 Set the SYNMET clock The date and the time of SYNMET are setting according the following scheme Choice of the day of week Ente...

Page 18: ...arometer and buffer accumulator which can be integrated into a slot of the SYNMET housing as a compact solution Figure Integrated barometer 10 4 2 Technical Data Accumulator maintenance free dryfit accumulator 12 V 0 8 Ah Barometer measuring range 800 to 1060 hPa Accuracy at 20 C 0 3 hPa Operating temperature 40 to 60 C More details refer to data sheet 10 5 Power distribution box This distribution...

Page 19: ...ion with the FMA 186 SYNMET up the firmware 3 0 With a sequence of commands ASCII characters different processes will carried out at SYNMET You can work with real time measured values or you can scan stored mean values later It is not required to develop difficult multitasking procedures You can write simple linear structured programs for the data aquisition without to fear a lost of data The deta...

Page 20: ...T for those customers working in the professional meteorological field a special firmware was developed It is generating coded messages according to the international standards of the World Meteorological Organization WMO the International Civil Aviation Organization ICAO and domestic weather services like METAR half hourly report SYNOP synoptic observations SPECI special weather messages 12 1 NME...

Page 21: ... literature thouroughly before calling our service staff When contacting our service staff by phone facsimile or e mail make sure to have all specific information at hand Wilh LAMBRECHT GmbH Mailing address Friedlander Weg 65 67 D 37085 Gottingen POBox address P O Box 2654 D 37016 Gottingen Phone 49 551 4958 0 Telefax 49 551 4958 312 e Mail wilh lambrecht t online de ...

Page 22: ...C V25 Clock rate 16 8 MHz Memory 512 KB EPROM 8 KB EEPROM 512 KB RAM battery buffered Real time clock 30 s month Power consumption approx 1 W Watchdog Multilayer board with EMV layers No potentiometers no jumpers Reparable IC technology no SMD technology Measured value collection with precise internal reference measurement and automatic line up 12 analog inputs Power source 1 10 mA Res meas 125 25...

Page 23: ...umeric keypad and multiple line LCD display for measured values Extension by keyboard measured value display and Memory Card storage unit CPU board as described above but additionally with extended numeric keypad and multiple line LCD display for measured values Memory Card for data storage Aluminium diecast case The aluminium diecast case according to DIN 1725 is EMC proof and can accommodate all...

Page 24: ...3 VA 1 DC DC converter 12 V DC 10 VA including relay output and Open Collector Power Supply Several different power supply modules are available to support a variety of applications Standard power supply module Input range 90 260 V AC Power 30 VA Universal power supply module with integrated charge regulator for internal external battery of up to 17 5 Ah Input range 90 260 V AC or 17 32 V DC or co...

Page 25: ... damping material should be used As the memory of the RAM on the CPU board will get lost after a certain time we recommend to load the configuration of the system by means of the test and configuration software FT 50 LITE The detailed use of it is described in a separate manual 17 0 Further technical manuals As mentioned before further manuals and literature is available from Lambrecht and is deli...

Reviews: