OPERATING INSTRUCTIONS 
METEODIGIT IV (9164) 

 

 

 

  

 
 

 

 

 

METEODIGIT IV

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Features 

METEODIGIT IV is a hand-held measuring instru-
ment. Optionally it can be connected with sensors for 
airflow, wind speed, relative humidity or air tempera-
ture. It provides a practical and cost-effective solution 
e.g. for production facilities, quality management, air 
conditioning technology and ventilating applications, 
on ships and in scientific laboratories. 

• 

Digital measuring technique 

• 

With null balance  

• 

Averaging, for each sensor individual adjustable and 
storable 

• 

Threshold value compensation 

• 

Automatic sensor recognition 

• 

Intelligent loading system 

• 

Compact and robust design 

• Simple 

operation 

• Fail-safe 
• 

High measuring accuracy 

 

Summary of Contents for METEODIGIT IV

Page 1: ...and cost effective solution e g for production facilities quality management air conditioning technology and ventilating applications on ships and in scientific laboratories Digital measuring techniq...

Page 2: ...tes Battery voltage 3 6V Unlocked for adjust purposes Measured value corrected Relative measuring Operating keys ON OFF Switch ON to switch OFF press long M M Meas point selection MAX MIN Max min valu...

Page 3: ...onitoring 6 7 2 Switching ON OFF reinitialization 6 8 CONNECTING THE SENSORS 6 8 1 1 Sensors 7 8 1 2 Measuring inputs and additional channels 7 9 DISPLAY AND KEYPAD 7 9 1 1 Display 7 9 1 2 Keypad 7 10...

Page 4: ...z The device is damaged by electrostatic dis charge or lightning z Improper handling respectively non observance of the operating instructions The manufacturer reserves the right to change the product...

Page 5: ...ot use the device inside detonation areas or filling stations 4 1 1 Special notes on use If the device is brought into the work room from a cold environment there is a risk that conden sation might fo...

Page 6: ...ement It is possible by setting the measured value to zero to perform relative measuring operations with respect to a reference value 6 INITIAL COMMISSIONING 1 Connect sensor to socket M0 1 2 Ensure t...

Page 7: ...igits b for depicting various measuring func tions a there are also 4 arrows f for depicting the operating status Function field Main field Display of measuring functions in the function field Measuri...

Page 8: ...d 55 Difference millivolt 1 mV d 26 Difference millivolt 2 mV d260 Difference volt V d2 60 Sensor voltage V UbAt Frequency Hz FrEq Function channels Maximum value of channel Mb1 Hi Minimum value of ch...

Page 9: ...CLR Select the next digit or entry is completed ON To terminate or cancel configuration MEM 11 1 Moving average METEODIGIT IV offers all the possibilities to calculate the average value In the first...

Page 10: ...e listed checks and reme dial steps the device still fails to behave as described in the operating instructions it must be returned to our factory in Goettingen with error description 13 DECLARATION O...

Page 11: ...ly not separated Housing L 127 x B 83 x H 42 mm ABS weight approx 260 g Suitable conditions Operating temperature 10 50 C storage temperature 20 60 C Ambient relative humidity 10 90 r h non condensati...