Electrical connection

The sensor will be connected to the cable by leading the cable through the conduit gland to the connector inside the 
sensor housing. Recommended cable type:
 

2 (4) x AWG 2O CU L sw;  

 

diameter approx. 5.1 mm

The cable should not be longer than 11 m.

When the cable is transferred inside the ground it is recommended to protect the cable with a protecting 
plastic tube.

USE OF THE BOUNCE-FREE OUTPUT SIGNAL (SEE FIGURE PAGE 8)

The usual circuit of the precipitation sensors is suitable for connection to data loggers without an own bounce-free 
impulse input. For this application the clamps 3 and 4 are used.

Make sure, that the current supply for the precipitation sensor with usual circuit is not less than 100 µA (see also 
technical data).

USE OF THE DIRECT OUTPUT SIGNAL (SEE FIGURE PAGE 9)

This circuit variant of the precipitation sensors is suitable for connection to data loggers with a bounce-free impulse 
input.   For this application the clamps 1 and 6 are used. In this case the current supply of the electronics with 100 µA 
is not necessary. The LAMBRECHT meteo data logger TROPOS is equipped with such a bounce-free input. Thus the 

direct output signal of the reed contact is used. An additional benefit is a low-current effect.

VERSION WITH HEATING 15189 H

Version i. e. with a controlled 2-circuit heating for collecting funnel and drain pipe.

ELECTRICAL CONNECTION OF THE HEATING

For the connection of the heating a 4-core cable is required, which has to apply and connect to the power supply unit 
according to the 

connecting diagrams

 with heating.

The 

function of the heating elements 

can be tested also at ambient temperatures above the control temperature 

of the solid-state thermostat. For this simple test a regular magnet has to be held close to the blue housing of the 

switching circuit. When reaching a surface temperature of approximately 50 °C the current will be switched off.

Both blue thermostat modules are fitted internally on the funnel surface as well 

as on the bottom of the housing. The operational conditions will be indicated 
with colored light-emitting diodes (LED) on the thermostatic module:

green:

   supply voltage

red:

  

heating on

red

green

Summary of Contents for 15189

Page 1: ...USER MANUAL Precipitation Sensor 15189...

Page 2: ...e specificguidelinesand orrulesforthepreventionofaccidents e g the professionalassociation Ifnecessaryaskyourresponsiblesafetyrepresentative 3 Use thesystemaccordingtothemanual s regulationsonly 4 Alw...

Page 3: ...transmittedandrecorded Abounce freesignal canbeachievedbyusingthecorrespondingelectricallyconnection Otherwisethesignalofthereedcontactcanbe useddirectly notbounce free ifthis functionwillbecarriedout...

Page 4: ...ecoveringcanbeturnedrighttothestop position andtakeoff upwardthen ASSEMBLY OF THE TIPPING BUCKET Toavoiddamagetothetippingbucketduringtransport itisseparatelypackedandshouldbeinsertedin theprecipitati...

Page 5: ...mantel Heizung die Wippe blockieren k nnten Einsetzen Entfernen Insert Remove A Tippingbucketbearings B Fixedlockingplate C Relocatablelockingplate D Reedcontact E Magnet hereshownthroughinclinationof...

Page 6: ...iontheclamps 1and 6areused Inthiscasethecurrentsupplyoftheelectronicswith100 A isnotnecessary TheLAMBRECHTmeteodataloggerTROPOSisequippedwithsuchabounce freeinput Thusthe directoutputsignalofthereed c...

Page 7: ...shouldhavecounted Rinse thesensorthoroughlyforcleaning Clingingparticlesofdirtinthecollectingfunneloroutletpipemaybe removedwitha pieceofwood Ifunsatisfyingmeasurementresultsoccurafterthiscleaningproc...

Page 8: ...aem eco LAMBRECHT meteo AEM 15189 page 8 with heating without heating CONNECTING DIAGRAMS FOR USE OF THE BOUNCE FREE SIGNAL OUTPUT...

Page 9: ...aem eco LAMBRECHT meteo AEM 15189 page 9 with heating without heating CONNECTING DIAGRAMS TO DATA LOGGER TROPOS...

Page 10: ...dards WMO No 8 VDI3786Sheet7 EN50081 82 VDE0100 15189 W4 Version with 4 cm3 bucket unheated Data as 00 15189 002000 but for high rainfall rates ID 00 15189 004000 Measuring range 4cm 4gwater volumeofb...

Page 11: ...ssteelmastforconcrete earthfoundation 00 15180 800050 Stainlesssteelmastforconcretefoundation withbaseplate 32 15180 021010 Bird defensering 33 15180 049000 Dirtpan sparepart 32 15188 060090 Connectio...

Reviews: