Installation

MOUNTING OF THE PRECIPITATION SENSOR

The precipitation sensor 15189 must be mounted on a tube or pole with an outside diameter of 60 mm. A metallic 

extension tube with a minimum length of 100 mm is recommended, if a wooden pole is used. For easy adjustment 
place a spirit-level on the upper measuring edge.

Attention! Do not damage the measuring edge!

Place the precipitation sensor 15189 on the end of the pole until it fits in. 

By using the provided allen key (4 mm) , tighten the screws in the mounting pedestal evenly. Adjust the upper 
measurement edge to an exact horizontal position. By doing this, the tipping bucket will automatically be positioned 
vertically inside the device and will works symmetrically.

DISMOUNTING OF THE PROTECTIVE COVERING

Loosening the screw with the provided 3 mm allen key until the protective covering can be turned right to the stop 

position and take off upward then.

ASSEMBLY OF THE TIPPING BUCKET

To avoid damage to the tipping bucket during transport, it is separately packed and should be inserted in 

the precipitation sensor (15189)

 

on site only after mounting the gauge on the mast. For the assembly first you 

must remove the protective covering. 

Attention!

 When fitting the tipping bucket, proceed with utmost caution so that the sharp edges of the 

tipping bucket are not damaged and the middle wall is not bent!

During operation the tipping bucket lies on the precision bucket bearings. To reduce the friction the bearings are 

made of abrasion-resistant delrin. The mounted tipping bucket is secured against eventual changes of position by 
means of two plates.

To insert the tipping bucket, first the relocatable locking plate 

C

  must be pushed back. Now insert the tipping bucket 

F

. Make sure that the magnet 

E

  attached at the middle wall of the tipping bucket rests under the capsule with the 

embedded reed contact 

D

. Finally the tipping bucket must be secured by pushing back the relocatable locking 

plate 

C

.

Summary of Contents for 15189

Page 1: ...USER MANUAL Precipitation Sensor 15189...

Page 2: ...e specificguidelinesand orrulesforthepreventionofaccidents e g the professionalassociation Ifnecessaryaskyourresponsiblesafetyrepresentative 3 Use thesystemaccordingtothemanual s regulationsonly 4 Alw...

Page 3: ...transmittedandrecorded Abounce freesignal canbeachievedbyusingthecorrespondingelectricallyconnection Otherwisethesignalofthereedcontactcanbe useddirectly notbounce free ifthis functionwillbecarriedout...

Page 4: ...ecoveringcanbeturnedrighttothestop position andtakeoff upwardthen ASSEMBLY OF THE TIPPING BUCKET Toavoiddamagetothetippingbucketduringtransport itisseparatelypackedandshouldbeinsertedin theprecipitati...

Page 5: ...mantel Heizung die Wippe blockieren k nnten Einsetzen Entfernen Insert Remove A Tippingbucketbearings B Fixedlockingplate C Relocatablelockingplate D Reedcontact E Magnet hereshownthroughinclinationof...

Page 6: ...iontheclamps 1and 6areused Inthiscasethecurrentsupplyoftheelectronicswith100 A isnotnecessary TheLAMBRECHTmeteodataloggerTROPOSisequippedwithsuchabounce freeinput Thusthe directoutputsignalofthereed c...

Page 7: ...shouldhavecounted Rinse thesensorthoroughlyforcleaning Clingingparticlesofdirtinthecollectingfunneloroutletpipemaybe removedwitha pieceofwood Ifunsatisfyingmeasurementresultsoccurafterthiscleaningproc...

Page 8: ...aem eco LAMBRECHT meteo AEM 15189 page 8 with heating without heating CONNECTING DIAGRAMS FOR USE OF THE BOUNCE FREE SIGNAL OUTPUT...

Page 9: ...aem eco LAMBRECHT meteo AEM 15189 page 9 with heating without heating CONNECTING DIAGRAMS TO DATA LOGGER TROPOS...

Page 10: ...dards WMO No 8 VDI3786Sheet7 EN50081 82 VDE0100 15189 W4 Version with 4 cm3 bucket unheated Data as 00 15189 002000 but for high rainfall rates ID 00 15189 004000 Measuring range 4cm 4gwater volumeofb...

Page 11: ...ssteelmastforconcrete earthfoundation 00 15180 800050 Stainlesssteelmastforconcretefoundation withbaseplate 32 15180 021010 Bird defensering 33 15180 049000 Dirtpan sparepart 32 15188 060090 Connectio...

Reviews: