Diaphragms
Boiler operation requires fitting the diaphragms supplied with the unit as instructed in the following tables and
drawings.
Choosing the diaphragm using coaxial pipes
Choosing the diaphragm using separate pipes
Type
Length up to:
Diaphragm to use
Coaxial
60/100
1 bend + 1 metre
Ø82 external
1 bend + 3 metres
No diaphragm
Pipe length
calculated in linear metres Diaphragm to use
Min
Max
0 m
20 m
Ø50 internal
20 m
35 m
No diaphragm
To change the diaphragm:
Diaphragm for coaxial pipes
Insert the diaphragm on the aluminium section
Ø60 of the upper flange of the boiler
Diaphragm for separate pipes
Insert the diaphragm under the flanged
air inlet section Ø80
Ø 82
Connection with coaxial pipes
Fit the concentric pipe, positioning it in the required direction, and insert the seal onto it and install the diaphragm
(when necessary). Fit the fume outlet and suction pipes observing the distances given on the respective installation
diagram. It is necessary to keep the fume outlet sloping slightly outwards.
CONCENTRIC OUTLET max length 3 m + bend
100 Max. 3000
220
Ø100
105
400
720
100
Max. 3000
229
320
Air
diaphragm
OUTLET
Taura 32 MCS
25
Ø 50
Summary of Contents for Taura 32 MCS
Page 92: ...92 Taura 32 MCS 1 93 2 94 3 99 4 a a 106 90 396 92 42 73 23 93 68 89 336 93 68...
Page 95: ...95 Taura 32 MCS 2 3 6 IV 25 Fr 6 C 2 4 7...
Page 103: ...103 Taura 32 MCS 3 2 1 3 4 3 3 1 1 5 bar...
Page 104: ...104 Taura 32 MCS A A B 4 1 2 3 4 10 15 5 5 1 A 2 3 B...
Page 105: ...3 4 3 led 3 1 RESET 1 RESET led 105 Taura 32 MCS 60 sec led led...
Page 110: ......
Page 111: ......