4.3 Technical data table
Powers
Pmax
Pmin
Heating Power (Net Heat Value - Hi)
kW
34.4
11.5
Available Thermal Power 80°C - 60°C
kW
31.3
9.7
Hot Water Heating Power
kW
31.3
9.7
Gas supply
Pmax
Pmin
Natural Gas main nozzles (G20)
mm
15x1.35
Natural Gas supply pressure (G20)
mbar
20.0
Pressure at Natural Gas burner (G20)
mbar
12.0
1.5
Natural Gas delivery (G20)
m
3
/h
3.64
1.22
LPG main nozzles (G31)
mm
15x0,79
LPG supply pressure (G31)
mbar
37.0
Pressure at LPG burner (G31)
mbar
35.0
5.0
LPG delivery (G31)
kg/h
2.69
0.90
Heating
Maximum working temperature in heating
°C
90
Maximum working pressure in heating
bar
3
Minimum working pressure in heating
bar
0.8
Expansion tank capacity
litres
10
Expansion tank pre-filling pressure
bar
1
Boiler water content
litres
1.2
Energy Efficiency Marking (EEC 92/42)
**
Hot water
Maximum hot water production
∆
t 30°C
l/min
14.9
Maximum working pressure in hot water production
bar
9
Minimum working pressure in hot water production
bar
0,25
Hot water content
litres
0,5
Electrical power supply
Max electrical power absorbed
W
90
Power voltage/frequency
V/Hz
230/50
Electrical protection rating
IP
X5D
Boiler weight
kg
31
4.4 Diagrams
Pressure - power diagrams
Head available for the system
mbar
kW
0
1
2
3
4
5
6
0
500
1.000
1.500
2.000
Q
[l/h]
H
[m H
2
O]
10
12
14
16
18
20
22
24
26
28
30
32
34
36
10
5
15
20
25
30
35
G31
LPG
G20
Natural
gas
Summary of Contents for Taura 32 MC
Page 91: ...TAURA 32 MC 91 Cod 3540F130 03 2007 Rev 00 2 3 6 IV 25 Fr 6 C 5 C 15 C 7 2 4 7...
Page 97: ...TAURA 32 MC 97 Cod 3540F130 03 2007 Rev 00 3 2 sez 4 4 1 3 4 3 3 1 1 5 bar...
Page 98: ...TAURA 32 MC 98 Cod 3540F130 03 2007 Rev 00 A A B 4 1 A 2 3 B 1 2 3 4 10 15 5...
Page 99: ...3 4 3 led 3 1 RESET 1 RESET led TAURA 32 MC 99 Cod 3540F130 03 2007 Rev 00 20 led led...
Page 104: ......
Page 105: ......