NINFA N 24 MCA
47
EN
cod. 3540P001 - 10/2008 (Rev. 00)
F40
Incorrect system water pres-
sure
Pressure too high
Check the system
Check the safety valve
Check the expansion tank
A41
Sensor positioning
Delivery sensor disconnected
from the pipe
Check correct positioning and operation of the heat-
ing sensor
F42
Heating sensor fault
Sensor damaged
Replace the sensor
F43
Exchanger protection acti-
vated.
No circulation of H
2
O in system
Check the circulating pump
Air in system
Vent the system
F47
System water pressure sen-
sor fault
Wiring disconnected
Check the wiring
F50
Modureg fault
Wiring disconnected
Check the wiring
Fault
code
Fault
Possible cause
Cure