Domestic hot water (DHW) temperature adjustment
Operate the DHW knob (detail 2 - fig. 1) to set the temperature between 40°C (min.) and 55°C (max.);
fig. 11
Room temperature adjustment (with optional room thermostat)
Using the room thermostat, set the temperature desired in the rooms. If the room thermostat is not installed the boiler
will keep the heating system at its setpoint temperature.
Room temperature adjustment (with optional remote timer control)
Using the remote timer control, set the temperature desired in the rooms. The boiler unit will set the system water ac-
cording to the required room temperature. For information on the remote timer control, please refer to its user's manual.
ECO/COMFORT selection
The unit is equipped with a function that ensures a high domestic hot water delivery speed and maximum comfort for
the user. When the device is activated (COMFORT mode), the water contained in the boiler is kept hot, therefore en-
suring immediate availability of hot water from the boiler on opening the tap, thus avoiding waiting times.
The device can be deactivated by the user (ECO mode) by turning the selector (detail 3 - fig. 1) to the RESET position
for 2 seconds and then to
(winter) or
(summer). To activate COMFORT mode, turn the selector (detail 3 - fig. 1)
to RESET again for 2 seconds and then to
(winter) or
(summer).
Sliding temperature
When the optional external probe is installed the boiler adjustment system works with "Sliding Temperature”. In this
mode the temperature of the heating system is adjusted according to the outside weather conditions, in order to guar-
antee high comfort and energy saving throughout the year. In particular, as the outside temperature increases, the sys-
tem delivery temperature is decreased according to a specific “compensation curve”.
With the Sliding Temperature adjustment, the temperature set with the heating knob (detail 1 - fig. 1) becomes the max-
imum system delivery temperature. It is advisable to set a maximum value to enable system adjustment throughout its
useful working range.
The boiler must be adjusted during the installation stage by qualified personnel. Adjustments can in any case be made
by the user to improve comfort.
Summary of Contents for NINFA 32 MCS
Page 160: ...NINFA 32 MCS 160 EL cod 3540G180 02 2008 Rev 00 5 1 9 1 2 6 1 9 1 3 Comfort Comfort 6 1 9 1 4...
Page 162: ...NINFA 32 MCS 162 EL cod 3540G180 02 2008 Rev 00 3 1 8 1 4 3 1 9 3 1 1 1 30 C 85 C 45 C 10...
Page 168: ...NINFA 32 MCS 168 EL cod 3540G180 02 2008 Rev 00 6 C A 18 R 18 30 18 2 4 B 27 B R1 A R2 R4 R3...
Page 178: ...NINFA 32 MCS 178 EL cod 3540G180 02 2008 Rev 00 3 2 B sez 4 4 sez 1 3 sez 4 4 3 3 1 bar...
Page 181: ...NINFA 32 MCS 181 EL cod 3540G180 02 2008 Rev 00 F37 F39 A41 F42 F43 H2O F50...