3.4 Troubleshooting
Diagnostics
The boiler is equipped with an advanced self-diagnosis system. In case of a boiler anomaly, the display will flash to-
gether with the fault symbol (detail 22 - fig. 1) indicating the fault code.
There are faults that cause permanent shutdowns (marked with the letter “
A
”): to restore operation just turn the selector
(detail 3 - fig. 1) to RESET (detail 8 - fig. 1) for 1 second or by means of the RESET on the Remote Timer Control (op-
tional) if installed; if the boiler fails to start, it is necessary to eliminate the fault indicated by the operation LEDs.
Faults marked with the letter “
F
” cause temporary shutdowns that are automatically reset as soon as the value returns
within the normal boiler operation range.
Table. 5 - Fault list
Code
fault
Fault
Possible cause
Cure
A01
Burner does not light
No gas
Check the regular gas flow to the boiler and that the air has
been eliminated from the pipes
Ignition/detection electrode fault
Check the wiring of the electrode and that it is correctly posi-
tioned and free of any deposits
Faulty gas valve
Check and replace the gas valve
Lighting power too low
Adjust the lighting power
A02
Flame present signal with burner
off
Electrode fault
Check the ionisation electrode wiring
Card fault
Check the card
A03
Overtemperature protection
intervention
Heating sensor damaged
Check correct positioning and operation of the heating sen-
sor
No water circulation in the system
Check the circulating pump
Air in the system
Vent the system
F04
Fume thermostat intervention
(after intervention of the fume
thermostat, boiler operation is
inhibited for 20 minutes)
Fume thermostat contact open
Check the thermostat
Wiring disconnected
Check the wiring
Flue not correctly sized or obstructed
Replace the flue
A06
No flame after the ignition phase
Low pressure in the gas system
Check the gas pressure
Burner minimum pressure setting
Check the pressures
F10
Delivery 1 sensor fault
Sensor damaged
Check the wiring or change the sensor
Wiring shorted
Wiring disconnected
F11
DHW circuit sensor fault
Sensor damaged
Check the wiring or change the sensor
Wiring shorted
Wiring disconnected
F14
Delivery 2 sensor fault
Sensor damaged
Check the wiring or change the sensor
Wiring shorted
Wiring disconnected
F34
Supply voltage under 170V.
Electric mains trouble
Check the electrical system
F35
Mains frequency fault
Electric mains trouble
Check the electrical system
F37
Incorrect system water pressure
System empty
Fill the system
Water pressure switch not con-
nected or damaged
Check the sensor
F39
External sensor fault
Probe damaged or wiring shorted
Check the wiring or change the sensor
Sensor disconnected after activating
the sliding temperature
Reconnect the external sensor or disable the sliding temper-
ature
A41
Sensor positioning
Delivery sensor disconnected from
the pipe
Check correct positioning and operation of the heating sen-
sor
F42
Heating sensor fault
Sensor damaged
Change the sensor
F43
Exchanger protection interven-
tion.
No H
2
O circulating in system
Check the circulating pump
Air in the system
Vent the system
F50
Modureg fault
Wiring disconnected
Check the wiring