• This booklet constitutes an integral and essential part of the product and should be supplied to the installer.
Read carefully the instructions contained in this booklet as they provide important directions regarding the
safety of installation, use and maintenance.
Preserve this booklet with care for any further consultation. The installation of the burner must be carried
out in compliance with current regulations, according to the instructions of the manufacturer and by qualified
personnel. An incorrect installation can cause injury or damage to persons, animals and objects, for which the
manufacturer cannot be held responsible.
• This appliance should be destined only for the use for which it has been expressly envisaged. Any other use is
to be considered improper and therefore dangerous. The manufacturer cannot be considered responsible for
any damages caused from improper, erroneous or unreasonable use.
• Before carrying out any cleaning or maintenance operation, disconnect the appliance from the power supply,
by using the main system switch or through the appropriate interception devices.
• In case of failure and/or malfunctioning, switch off the equipment and refrain from trying any repair or direct
intervention. Call in qualified personnel only. Any repair must be carried out by a servicing centre authorised
by the manufacturing firm, one using original replacements exclusively. Non-observance of the above could
compromise the safety of the appliance.
In order to guarantee the efficiency of the appliance and its proper operation it is indispensible to keep to the
manufacturer’s directions, by ensuring the periodical servicing of the appliance is carried out by professionally
qualified personnel.
• As soon as one decides not to use the appliance further, one should take care to render innocuous those parts
liable to be potential sources of danger.
• The transformation from a gas (natural gas or liquid gas) to a gas of another group must be made exclusively
by qualified personnel.
• Before starting up the burner for the first time ask qualified personnel to check:
a) that the data on the information plate corresponds to that required by the gas, and electrical supply networ-
ks;
b) that the calibration of the burner is compatible with the boiler output;
c) that the comburent air flow and the fumes evacuation take place properly in accordance with the regulations
in force.
d) that correct aeration and maintenance are possible.
• After each reopening of the gas cock wait a few minutes before restarting the burner.
• Before carrying out whatever intervention which foresees the dismantling of the burner or the opening of any
of the accesses for inspection, disconnect the electrical current and close off the gas cocks.
• Do not deposit containers of inflammable substances in the location where the burner is situated.
• On noticing the smell of gas do not touch any electrical switch. Open all doors and windows. Shut off the gas
cocks. Call qualified personnel.
• The room where the burner is located must have the openings required by local regulations in force. Should
you have any doubts as to the circulation of the air in the room, then you should first measure the CO
2