![Lamborghini Caloreclima IDOLA SW-T 3.2 Installation, Maintenance And User Manual Download Page 121](http://html1.mh-extra.com/html/lamborghini-caloreclima/idola-sw-t-3-2/idola-sw-t-3-2_installation-maintenance-and-user-manual_3401740121.webp)
121
EN
&RG05HY
,'2/$6:7
10.3.2 Temperature curves for cooling mode
&/,0$7,&&859(6:76&22/,1*02'(
T4 (T_outdoor_air) [°C]
-10
14
15
21
22
29
30
46
id Climatic curve
7HUPLQDO7\SH
selected on remote
controller
Climatic curves
set
T1S or T2S
:DWHUIORZ7HPS>&@
16,0
16,0
11,0
11,0
8,0
8,0
5,0
5,0
1
Fancoil
C1
17,0
17,0
12,0
12,0
9,0
9,0
6,0
6,0
2
18,0
18,0
13,0
13,0
10,0
10,0
7,0
7,0
3
19,0
19,0
14,0
14,0
11,0
11,0
8,0
8,0
4
20,0
20,0
15,0
15,0
12,0
12,0
9,0
9,0
5
21,0
21,0
16,0
16,0
13,0
13,0
10,0
10,0
6
22,0
22,0
17,0
17,0
14,0
14,0
11,0
11,0
7
23,0
23,0
18,0
18,0
15,0
15,0
12,0
12,0
8
20,0
20,0
18,0
18,0
17,0
17,0
16,0
16,0
1
Radiant floor Heating
or radiator
C2
21,0
21,0
19,0
19,0
18,0
18,0
17,0
17,0
2
22,0
22,0
20,0
20,0
19,0
19,0
17,0
17,0
3
23,0
23,0
21,0
21,0
19,0
19,0
18,0
18,0
4
24,0
24,0
21,0
21,0
20,0
20,0
18,0
18,0
5
24,0
24,0
22,0
22,0
20,0
20,0
19,0
19,0
6
25,0
25,0
22,0
22,0
21,0
21,0
19,0
19,0
7
25,0
25,0
23,0
23,0
21,0
21,0
20,0
20,0
8
4
6
8
10
12
14
16
18
20
22
24
-10
0
10
20
30
40
50
COOLING MODE (climatic curves set C1)
1
2
3
4
5
6
7
8
14
16
18
20
22
24
26
-10
0
10
20
30
40
50
COOLING MODE (climatic curves set C2)
1
2
3
4
5
6
7
8
Climatic curve 9 in cooling mode settable by the user
7KHFOLPDWLFFXUYHLVGHILQHGE\SDUDPHWHUVWKDWFDQEHVHWE\WKHXVHU7&7&76(7&76(7&UHIHUWR³6HUYLFHSDUDPHWHUVWDEOH´RQSDJH
T4C1
T4C2
T1SETC2
T1SETC1
T4
T1S (T1S2)
fig. 41 - Climatic curve 9 in cooling mode
Summary of Contents for IDOLA SW-T 3.2
Page 67: ...67 IT RG 0 5HY 2 6 7 NOTE...
Page 131: ...131 EN RG 0 5HY 2 6 7...
Page 195: ...195 PL RG 0 G 2 6 7...