44
OPERATING SEQUENCE (display only)
Step
Function
0
pause, no heat required
1
pre-ventilation
2
ignition
3
burner ignited (heating system mode)
4
burner ignited (hot water mode)
5
air pressure switch control
6
burner off (water temp. more than 5
°
C warmer than setting)
7
post-circulation pump in heating mode
8
post-circulation pump in hot water mode
9
burner off because of fault (see shutdown code)
During boiler operation the first figure on the digital display indicates the sequence step while the
second gives the temperature of the water in the boiler.
E.g.
means that the unit is heating at a delivery temperature of around 80
°
C.
Button
Function
ON/OFF
ON/OFF SWITCH
SUMMER/WINTER SWITCH
RIARMO/RESET
BOILER RESET
PROG./MODE
PROGRAM SELECTOR
(DISPLAY)
Button
Function
SEQUENZA/STEP
SELECTS PARAMETERS TO BE
DISPLAYED
MEMO/STORE
ENTERS DATA
+
INCREASES SETTING
-
DECREASES SETTING
HOT WATER ADJUSTMENT
0-60
°
C
61
CIRCUITO HIDRÁULICO
DESCRIPCIÓN
A
Gas
B
Entrada agua fría
C
Salida agua caliente sani-
taria
D
Ida instalación
E
Retorno instalación
1
Sonda de control ida
instalación
2
Purgador automático aire
3
Electrodo de control
4
Acoplamiento inyector
5
Electrodos de encendido
6
Transformador de
encendido
7
Ventilador
8
Presostato aire
9
Sonda de control retorno
instalación
10
Válvula gas
11
Sifón para descarga
condensación
12
Circulador
13
Vaso de expansión circui-
to calefacción 8 l.
14
Presostato falta de agua
15
Válvula de seguridad
16
Hidrómetro
17
Grifo de llenado
18
Grifo de vaciado
19
Acumulador 90 l.
20
Vaso de expansión circui-
to sanitario 3 l.
21
Sonda acumulador
22
Ánodo de magnesio
23
Válvula de seguridad
acumulador
24
Válvula de 3 vías