cod. 3541T630 - Rev. 04 - 12/2021
88
EN
DORA
200 HT - 260 HT
4.2 Technical characteristics
Model
200 HT
260 HT
-
Heat pump
Power supply
230-1-50-1PH
V-PH-Hz
Thermal power (UNI)
1600
1600
W
Total absorbed power in heating (UNI)
370
370
W
COP (UNI)
4.32
4.32
W/W
Rated current in heating (UNI)
1.70
1.70
A
Max. total absorbed power in heating
500
500
W
Max. current in heating
2.30
2.30
A
Heating time (EN) (1)
7:16
9:44
h:min
Heating energy (EN) (1)
2.83
3.74
kWh
Standby consumption (EN) (1)
27.3
31
W
Class of use (EN) (1)
L
XL
Type
Power consumption during operating cycle WEL-TC (EN) (1)
4.18
6.17
kWh
COPDHW (EN) (1)
2.80
3.10
W/W
COPDHW (EN) (4)
2,50
2,60
W/W
Water reference temperature (EN) (1)
51.4
53.7
°C
Max. usable amount of water( EN) (2)
0.260
0.358
m
3
Heating efficiency ref. standard (EU)
116
127
%
Efficiency class ref. standard (EU)
A+
A+
-
Yearly power consumption (EU)
883
1315
kWh/year
Electrical heating element
Power
1500
1500
W
Current
6.5
6.5
A
Heat pump +
Electrical heating element
Total absorbed power
1870
1870
W
Rated current
8.20
8.20
A
Total max. absorbed power
2000
2000
W
Max. current
8.80
8.80
A
Heating time (1) BOOST MODE
3:48
4:57
h:min
Storage
Storage capacity
192
250
l
Max. pressure
0.7
0.7
MPa
Material
Enameled steel
type
Cathodic protection
Mg rod anode
type
Insulation type\thickness
polyurethane/50
type/mm
Air circuit
Fan type
Centrifugal
type
Air flow rate
350
350
m³/h
Duct diameter
160
160
mm
Max. available head
100
100
Pa
Refrigeration circuit
Compressor
Rotary
type
Refrigerant
R134a
type
Evaporator
Aluminum - Aluminum
Finned coil
type
Condenser
Aluminum tube wound outside tank
type
Internal sound power levels (3)
52
52
dB(A)
External sound power levels (3)
50
50
dB(A)
Empty weight
Net
86
98
kg
NOTES
•
(UNI):
data according to standard
UNI EN 16147:2017
•
(EU):
data according to regulation
2017/1369/EU
•
(1):
Heating cycle Air inlet temp = 20°C DB/15°C WB Initial water temperature 10°C
•
(2):
Operating temperature limit 40°C - Water inlet temperature 10°C
•
(3):
data according to standard
EN 12102-1:2018 ECO MODE A 20°C DB/15°C WB
•
(4):
Heating cycle Air inlet temp = 14°C DB/13°C WB Initial water temperature 10°C