69
ANTI-FREEZE KIT (ON REQUEST)
The LAMBY boiler is fitted as standard with an anti-freeze device that protects the hydraulic circuit. This device
is tripped when the temperature falls to about 6
°
C. The hot water circuit can be provided with even better
protection by installing an ANTI-FREEZE KIT which starts functioning at 4
°
C.
ANTI-FREEZE KIT components
1
Adhesive element 72x42-230V-12 W
2
Adhesive element 200x53-230V-30 W
3
Anti-freeze thermostat 4
°
C-14
°
C
4
Silicon insulating hood
5
Insulating sheath internal Ø16 mm x 70 mm
6
Wire plug
7
Self-tapping screws
8
Holder strap
9
Element wire ring clip
10
Rapid exchanger
11
Electric board
12
Cold water inlet
13
Hot water outlet
14
Hot water inlet
INSTALLING THE ELEMENTS
Apply the elements
1
and
2
; fit them the right way round as
illustrated. Fix the thermostat
3
onto the base located on the
hot water inlet pipe using the screws
7
. Insert the electrical
wires in the junction box making sure that the supplied wire
plug
6
is positioned correctly. Connect the wires to the FA1/
FA2 terminals as illustrated (see detail
B
).
Detail A
Detail B