Page 27
Level
Display
Function
Factory
setting
Range
Selection
E3-2 / 1
TDE1
Switch-on temperature
difference for storage reservoir
1 between F1 and F4 (not less
than switch-off temperature
diff 1 K).
8 K
1 K to 20 K
E3-2 / 2
TDA1
Switch-off temperature
difference for storage reservoir
1 between F1 and F4 (not
greater than switch-on
temperature difference - 1 K).
4 K
1 K to 20 K
E3-2 / 3
TDE2
Switch-on temperature
difference for storage reservoir
2 between F1 and F6 (not less
than switch-off temperature
diff 1 K).
8 K
1 K to 20 K
E3-2 / 4
TDA2
Switch-off temperature
difference for storage reservoir
2 between F1 and F6 (not
greater than switch-on
temperature difference - 1 K).
4 K
1 K to 20 K
E3-2 / 6
USW1
Minimum switch-on duration for
solar pump.
Note: if the USW1 value is set to
100%, the speed control
function is deactivated!
30%
30% to OSW1
E3-2 / 7
OSW1
Maximum switch-on duration for
solar pump.
100%
USW1 to 100%
E3-2 / 8
USW2
Minimum switch-on duration for
solar pump 2.
Note: if the USW2 value is set to
100%, the speed control
function is deactivated!
30%
30% to OSW2
E3-2 / 9
OSW2
Maximum switch-on duration for
solar pump 2.
100%
USW2 to 100%
Additional functions:
See the overviews in section
5.3. Possible additional functions
, section
5.4. Relay connector assignment
and
section
5.5. Sensor connector assignment.
For detailed descriptions of the individual additional functions, see section
10. Setting the additional functions
.
Configuration of system layouts