Manual hot water loading
With this function you can manually reload the hot water storage tank, that means, you get hot water in times,
when your heating and your hot water support are normally switched off. You manually change the tempera-
ture level of the hot water until the next switching time or until the hot water loading is finished. Move to the
submenu by pressing the key two times. With the keys or choose day-, night- or economy
level. Acknowledge with the key .
Adjustment
Symbol
Meaning
Manual choice of hot
water loading
Automatic regulation of the hot water loading according to the
adjustments.
Enable manual hot water
loading
The hot water storage tank is reloaded. On the display the symbol
appears. The enabling is valid until the next switching time
(one time loading).
Enable manual hot water
loading with economy
level
The hot water storage tank is reloaded. On the display the symbol
appears. The enabling is valid until the next switching time
(one time loading).
Block manual hot water
loading
The hot water loading is blocked. On the display the symbol
appears. The blocking is valid until the next switching time.
12.
Submenu information
This submenu shows the temperatures of the connected sensors. It depends on your heating system and its
configuration, which sensors are mounted at your heating system. For this reason it is possible, that your
controller does not display all values, that are shown in the following chart.
Coming from the starting display press the key two times, until ”
i
“ appears on the display. Acknowledge
with the key and you will get to the temperature display.
On the display
Meaning
F1
TA
Outside temperature
F2
TK
Boiler temperature
F3
TV
Flow temperature
F4
TW
Water temperature
F1-F5
TI, TR,
TF, KF
Depending on the configuration: room temperature (TI), return flow temperature
(TR), floor heating temperature (TF) or jumper for boiler value control (KF)
F8
TI, KF
Room temperature, that is measured by an analog remote control (TI) or jumper for
boiler value control (KF)
The symbol
(serial interface active) appears in the display in addition to the shown value, that is
transferred by another bus sharing unit. The values of the sensors are not shown in the display anymore.
+