Technical Data

All specifications are typical at nominal line, full load,25

; Unless otherwise specified.

o

C

Installation

Read Instructions!

  Before working with this unit, read these instructions
  carefully and completely. Make sure that you have
  understood all the information!

Disconnect system from supply network

  Before any installation, maintenance or modification work:
  Disconnect your system from the supply network. Ensure that it
  cannot be re-connected inadvertently!

In operation: No modifications!

  As long as the unit is in operation: do not modify the
  installation! The same applies also to the secondary side. Risk
  of electric arcs and electric shock (fatal)!

 Only connect/disconnect when the power
 is off!

Convection cooling (See Fig.1)

  

Do not cover

 any ventilation holes!

  

Leave sufficient space

 around the unit 

for cooling!

  

Warning: High voltage! Stored energy!

  The unit contains unprotected conductors carrying a lethal
  high voltage, and components storing substantial amounts of
  energy. Improper handling may result in an electric shock or
  serious burn!
    The unit must not be opened except by appropriately trained
    personnel!
    Do not introduce any object into the unit!
    Keep away from fire and water!

Removal

 from DIN Rail (See Fig. 4)

    Push the slider downwards (unlock). Gently lift
    lower front edge of the unit (tipping) and remove.

Safety notes

  Permissible mounting position: keep ventilation holes clear,
  leave space for cooling! Recommended to have 25mm
  free space at all sides:

Snap on support rail 

(See Fig. 2)

    Tilt the unit slightly rearwards.
    Fit the unit over top hat rail.
    Slide it downward until it hits the stop.
    Press against the bottom front side for locking.
    Shake the unit slightly to check the locking action.

Before start of operation
Ensure appropriate installation

  Warning! Improper installation / operation impair safety and
  result in operational difficulties or complete failure of the unit.
  The unit must be installed and put into service appropriately
  by qualified personnel. Compliance with the relevant
  regulations must be ensured. Before operation is begun the
  following conditions must be ensured, in particular:
    Connection to main power supply in compliance with
    VDE0100 and EN50178.
    With stranded wires: all strands must be secured in the
    terminal blocks (potential danger of short circuit).
    Unit and power supply cables must be properly fused; if
    necessary a manually controlled disconnecting element must
    be used to disengage from supply mains.
    The non-fused earth conductor must be connected to the
    "     " terminal (protection class 1).
    All output lines must be rated for the power supply output
    current and must be connected with the correct polarity.
    Sufficient air-cooling must be ensured.

Connection 

(See Fig. 3)

    Use only commercial cables designed for the indicated
    voltage and current values!
    With flexible cables: make sure that all stranded cable are
    secured in the terminal.
    Ensure proper polarity at output terminals!

Model No.

DPP15-24

DPP25-5

DPP30-12

DPP30-24

DPP50-15

DPP50-24

DPP50-48

DPP100-24

Description

Input

Rated input Voltage

AC Voltage Range

DC Voltage Range

Frequency

Rated input Current  

Inrush Current(115Vac/230Vac)

Efficiency Typ.

Power Factor Correction

115/230 Vac auto select

85-132 / 176-264

210-375 Vdc

2.2/1.2A 

Typ.<35A / Typ.<55A

87%

1.1/0.7A

1.1/0.7A

1.1/0.7A

0.7/0.4A

0.7/0.4A

0.6/0.4A

0.4/0.25A
Typ.<35A

Typ.<35A / Typ.<45A

Typ.<35A / Typ.<50A

115Vac / 230Vac

85 - 264Vac

90-375Vdc

50 / 60Hz

80%

78%

82%

84%

85%

86%

87%

meet EN61000-3-2 class A

Output

Turn on time

Voltage Rise Time

Overvoltage protection

Voltage trim range

Line regulation

Load regulation

Time & temp. Drift

Initial voltage setting

DC ON indicate(Green LED)

Ripple

Nominal Current

Rated over load protection

Current Limit

Holdup Time(115Vac/230Vac)

Voltage fall Time

Parallel Operation

>30 but <33Vdc

<6.7Vdc

<18Vdc

>30 but <33Vdc

<20Vdc

>30 but <33Vdc

<66Vdc

>30 but <33Vdc

22.5-28.5 Vdc

5-6 Vdc

9.9-12.1 Vdc

22.5-28.5 Vdc

11.9-15.1 Vdc

22.5-28.5 Vdc

48-56 Vdc

22.5-28.5 Vdc

<1000mS after AC is applied to input at full resistiv

e load

<150mS  full resistive load

<0.5%

<0.5%

<1.0%

24.5V   1%

5V   1%

12V   1%

24.5V   1%

15V   1%

24.5V   1%

48V   1%

24.5V   1%

>18V

>4V

>7.92V

>18V

>9.52V

>18V

>38.4V

>18V

<50m Vp-p

0.6A

5A

2.5A

1.3A

3.4A

2.1A

1.0A

4.2A

110%~150%

120%~135%

135%~160%

120%~150%

135%~155%

120%~150%

125%~145%

115%~140%

Fold Forward (Current rises, voltage drops to maintain constant power during overload p to max peak current)

>20ms / >25ms

<150mS from 95% to 10% rated voltage @ full load

Switch selectable Via front panel------DPP 100-24 model only

General

Emissions
Immunity

Approvals

EN61000-6-3,EN55011,EN55022 Class B Radiated and Conducted including Annex. A.

EN61000-6-2,EN61000-4-2 Level 4,EN61000-4-3 Level 3,EN61000-4-6 Level 3,

EN61000-4-4 Level 4 input and level 3 output. EN61000-4-5 level 4,EN61000-4-8,EN61000-4-11

EN60950-1,UL508 Listed, UL 60950-1, NEC Class 2 except DPP100-24, CE marked for EMC(89/336/EEC)

Temperature

Humidity

MTBF(MIL-HDBK-217F.GF25)
Case

Dimensions
H x W x D(inches / mm)

Weight

2.95 x 0.9 x 3.81

(75 x 22.8 x 96.7)

2.95 x 1.77 x 3.58

(75 x 45 x 91)

42.95 x 2.85 x 3.81

(75 x 72.5 x 96.7)

130g

260g

390g

Plastic

287,000 hrs

294,000 hrs

288,000 hrs

304,000 hrs

269,000 hrs

273,000 hrs

283,000 hrs

239,000 hrs

20%~90%RH

Storage:-25 to +85  , Operation-10 to+ 60  derating to half power from 60 to 70 

o

o

o

C

C

C

Mounting 

(See Fig. 1)

JAN05-01

Fuse Rating (Internal)

T1AH,250V

T2AH/250V

T3.15AH/250V

IP rating

IP 20