Tying In
Towers must be tied into a suitable rigid structure once they go beyond the freestanding working heights
specified in BS EN 1004-1:2020 - 8m working platform height outdoors and 12m working platform height
indoors - or if the tower is unstable or is in danger of being unstable. Standard scaffold tubes and fittings
can be used with Alto Access tower products. Ties should be spaced at no more than 4m intervals. Ties
must be rigid in tension & compression and be secured to both frame uprights. For further details
regarding tying in, please contact your supplier or the manufacturer: Lakeside Industries Limited.
Signage
After assembly or alteration, the following minimum information shall be displayed on the mobile access
and working tower and be clearly visible from the ground (e.g. on a tag):
·
The name and contact details of the responsible person.
·
If the tower is ready for application or not.
·
The load class and the uniformly distributed load.
·
If the mobile access and working tower is intended for indoors use only.
·
The date of assembly.
Safety Pictograms