6. Instrument application   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7. Technical specification 

 

Item 

Parameter   

Laser wavelength 

LS526: 635nm    LSG526: 532nm 

Laser class 

Class

/

 

Output range 

LS526: 600m    LSG526: 400m 

Rotating speed 

600 rpm   

Area scanning angle   

Big area scanning/small area scanning/dot   

Accuracy   

±0.75mm/10m 

Leveling range 

±5° 

Working temperature 

-10

℃~

+45

 

Summary of Contents for LS526

Page 1: ...ronic auto leveling when beyond the range the instrument stops rotating and sound indication 360 rotary laser able to work horizontally and vertically Able to set different rotation speed and area scanning angle Able to unbalance alarm in TILT mode The instrument stops rotating when knocked in order to make sure work accurately Slope mode function could set single axis or double axis slope Accurac...

Page 2: ...ording to polarity direction then fix the battery box on the instrument b Fix the rechargeable battery on the instrument 4 2 Charging to rechargeable battery Central 5 8 screw thread Side 5 8 screw thread Battery cover screw Remote receiving tube Battery cover Laser output window Hand wheel Rotary head Operation keypad ...

Page 3: ...nstrument Note a When the power LED is flashing the battery is in low voltage It can extend the life of the battery when charging the battery as the battery is use up b Charging once to rechargeable battery every two or three months since the instrument leaving factory 4 3 Placement of the instrument Instrument in horizontal placement a Place on a horizontal platform directly b Connect with the tr...

Page 4: ...eration keypad Slope move leftwards key TILT mode key Self leveling key X direction slope LED Y direction slope LED Remote status LED TILT mode LED Slope function key Remote shielding key Area scanning dot move clockwise key Area scanning dot move anti clockwise key Power LED On off key Area scanning function Rotation speed set key Slope move rightwards key ...

Page 5: ...witched to low speed and the rotation speed is 200rpm 4 7 Area Scanning function key a When the instrument is rotating press this key to enter the area scan mode the instrument enter into big area scanning status press this key again enter into small area scanning status press this third time enter into dot status the area scanning order will be switched as follows 4 8 Area scanning moving key a U...

Page 6: ...X LED is on Z axis is self leveling Y direction LED is flash press slope left right moving key could make slope adjustment long press to exit slope adjustment function 4 11 Self leveling key Press this key the instrument will enter into self leveling status the instrument is in TILT alarming status press this key the instrument exit alarming status and make leveling after leveling TILT mode still ...

Page 7: ... by 90 degrees in turn after the instrument is auto leveling mark the point of intersection of the laser line and the vertical line as point B C and D separately 4 Measure the maximal distance h between two points which among point A B C D 5 If h 3mm the accuracy is OK If 3mm h 20mm the accuracy is beyond tolerance the user could adjust and calibrate the accuracy If h 20mm the accuracy is beyond t...

Page 8: ...key on remote control Y calibration LED on instrument keypad flash the instrument will enter into Y direction calibration c Press self calibration adjustment on remote control the laser line move up and down until it coincides with dot O 4 Calibration confirmation When X direction and Y direction confirmation are finished press self calibration confirmation key calibration LED is off calibration v...

Page 9: ... Parameter Laser wavelength LS526 635nm LSG526 532nm Laser class ClassⅡ Ⅲ Output range LS526 600m LSG526 400m Rotating speed 600 rpm Area scanning angle Big area scanning small area scanning dot Accuracy 0 75mm 10m Leveling range 5 Working temperature 10 45 ...

Page 10: ...nt Do not attempt to disassemble the instrument and the unprofessional disassembly will result in the damage of instrument Keep the cleanness of instrument especially the laser output window and remove dust by the gentle operation of soft clean cloth Take the batteries out when the instrument is not in use for a long time and keep the instrument in the carrying case when it is unused Although the ...