 Parameter Name  

 Default Value  

 Description  

Logging Threshold 

- 99 dBm 

Tracers with RSSI value less than this threshold will be ignored 

 Alarms 

RANGE A

 

Range A Proximity Alarm 1 Timer 

3 sec 

Seconds of proximity to a remote tracer before triggering alarm 1 

Range A Alarm 1 RSSI Threshold 

-52 dBm 

Trigger alarm if a tracer is detected with signal greater than this value 

Range A Alarm 1 Red LED 

Indicator 

Style 1 

Selects style for the red LED indicators when alarm 1 is triggered 

Range A Alarm 1 Speaker 

Indicator 

Style 4 

Selects style for the speaker indicator when alarm 1 is triggered 

Range A Alarm 1 Vibe Indicator 

Off 

Selects style for the vibration motor indicator when alarm 1 is triggered 

Range A Alarm Intensity 

High 

Normal intensity speaker/vibe indicator level 

Range A Proximity Alarm 2 

600 sec 

Seconds of proximity to a remote tracer before triggering alarm 2 

Range A Alarm 2 Red LED 

Indicator 

Style 1 

Selects style for the red LED indicators when alarm 2 is triggered 

Range A Alarm 2 Speaker 

Indicator 

Style 1 

Selects style for the speaker indicator when alarm 2 is triggered 

Range A Alarm 2 Indicator Styles 

Style 4 

Selects style for the vibration motor indicator when alarm 2 is triggered 

Range A Alarm 2 Intensity 

Low 

Low intensity speaker/vibe indicator level 

RANGE B

 

Range B Proximity Alarm 1 Timer 

3 sec 

Seconds of proximity to a remote tracer before triggering alarm 1 

Range B Alarm 1 RSSI Threshold 

-60 dBm 

Trigger alarm if a tracer is detected with signal greater than this value 

Range B Alarm 1 Red LED 

Indicator 

Style 3 

Selects style for the red LED indicators when alarm 1 is triggered 

Range B Alarm 1 Speaker 

Indicator 

Off 

Selects style for the speaker indicator when alarm 1 is triggered 

Range B Alarm 1 Vibe Indicator 

Off 

Selects style for the vibration motor indicator when alarm 1 is triggered 

Range B Alarm Intensity 

High 

Normal intensity speaker/vibe indicator level 

Range B Proximity Alarm 2 

600 sec 

Seconds of proximity to a remote tracer before triggering alarm 2 

Range B Alarm 2 Red LED 

Indicator 

Style 3 

Selects style for the red LED indicators when alarm 2 is triggered 

Range B Alarm 2 Speaker 

Indicator 

Style 3 

Selects style for the speaker indicator when alarm 2 is triggered 

Range B Alarm 2 Indicator Styles 

Off 

Selects style for the vibration motor indicator when alarm 2 is triggered 

Range B Alarm 2 Intensity 

Low 

Low intensity speaker/vibe indicator level 

RANGE C

 

Range C Proximity Alarm 1 Timer 

3 sec 

Seconds of proximity to a remote tracer before triggering alarm 1 

Range A Alarm 1 RSSI Threshold 

-71 dBm 

Trigger alarm if a tracer is detected with signal greater than this value 

Range C Alarm 1 Red LED 

Indicator 

Off 

Selects style for the red LED indicators when alarm 1 is triggered 

Summary of Contents for Sentrius BT710

Page 1: ...A Version 0 4...

Page 2: ...3 0610 Version Date Notes Contributor Approver 0 1 14 Aug 2020 Initial preliminary release Scott Lederer Chris Boorman 0 2 10 Sept 2020 Revised some functional definition and added further operational...

Page 3: ...tyles 8 3 9 Care and Maintenance 8 4 Contact Tracer Architecture 9 4 1 Bluetooth Advertisements 9 4 1 1 1M PHY 9 4 1 2 1M PHY Scan Response 9 4 1 3 Ad Record Types 9 4 2 Bluetooth Advertisement Field...

Page 4: ...bt7x0 tracker multi sensor 4 Copyright 2020 Laird Connectivity Inc All Rights Reserved Americas 1 800 492 2320 Europe 44 1628 858 940 Hong Kong 852 2923 0610 8 Ordering Information 18 9 Label Info 18...

Page 5: ...luding four bright red LEDs a bi color status LED an audible speaker and a vibration motor on wrist worn models For proximity sensing applications where local alarm indication is desired the BT710 off...

Page 6: ...dicator styles There are two low power modes Non Active and Power Save The tracer automatically enters these modes based on motion detection to extend battery life User configurable parameters control...

Page 7: ...y the Ad Interval parameter The advertisement data contains identifiers to help filter out non tracer devices including device ID TX power and other status information Flags in the advertisement indic...

Page 8: ...tab of the BT710 mobile application When configuring the alarm style the BT710 mobile application will trigger the new alarm style on the BT710 tracer to show the new alarm style note Save Changes mus...

Page 9: ...nd or data log download The Bluetooth tracking device can be configured to transmit with an output power of 20 to 8 dBm Table 3 1M PHY Byte Description Value Notes 0 0x02 Length 0x02 1 GAP_ADTYPE_FLAG...

Page 10: ...VED 0 Reserved 1 Motion Reserved Bit 3 0x0008 LOW_BATTERY 0 Battery good 1 Battery low Bit 4 0x0010 DATALOG_FULL 0 Datalog is not full 1 Datalog is full This is the device ID currently advertised by t...

Page 11: ...tween advertisement TX events Active Mode Active Motion Timeout 300000 ms Milliseconds of no motion to trigger Non Active Mode from Active Mode Non Active Scan Interval 120 sec Seconds between scan di...

Page 12: ...on motor indicator when alarm 2 is triggered Range A Alarm 2 Intensity Low Low intensity speaker vibe indicator level RANGE B Range B Proximity Alarm 1 Timer 3 sec Seconds of proximity to a remote tra...

Page 13: ...where batteries are changed about once a month If more time is necessary the scan interval can be increased scan less frequently the scan duration can be decreased scan for a shorter time period or t...

Page 14: ...n time in the database After any remote is detected in enough scans such that total detection time crosses a configured alarm threshold the configured alarm indicators are triggered to alert the user...

Page 15: ...l they are detected up to the maximum records that can be recorded for the duration of the Tracking Phase set with the Tracking Duration parameter Untracked Phase If a remote tracer has been detected...

Page 16: ...he applicable app store Apple or Android search for and install the Sentrius BT710 mobile application on your mobile device 2 To connect to the BT710 make sure it is in Active mode 3 Tap FIND BT7 DEVI...

Page 17: ...nnect com iot devices iot sensors sentrius bt7x0 tracker multi sensor 17 Copyright 2020 Laird Connectivity Inc All Rights Reserved Americas 1 800 492 2320 Europe 44 1628 858 940 Hong Kong 852 2923 061...

Page 18: ...with Wrist Strap Single Single 1 450 00122B SentriusTM BT710 Bluetooth tracking device with Clip BULK Bulk 100 450 00059B SentriusTM BT710 Bluetooth tracking device BULK Bulk 100 450 00134B K1 Sentri...

Page 19: ...by Laird Connectivity and its agents is believed to be accurate and reliable All specifications are subject to change without notice Responsibility for the use and application of Laird Connectivity m...

Reviews: