This is always 0x0077, the Company ID for Laird Connectivity.
This is always 0xFF81, the protocol for the BT510-CT and BT710 tracers.
This is user programmable via the NETWORK_ID parameter. Defaults to 0xFFFF.
Table 6: Flags field
Flag Bit
Name
Description
Bit 0 (0x0001)
HAS_EPOCH_TIME
0
Clock time not set
1
Clock time set
Bit 1 (0x0002)
HAS_LOG_DATA
0
Data log not ready
1
Data log ready for download
Bit 2 (0x0004)
RESERVED
0
Reserved
1
Motion Reserved
Bit 3 (0x0008)
LOW_BATTERY
0
Battery good
1
Battery low
Bit 4 (0x0010)
DATALOG_FULL
0
Datalog is not full
1
Datalog is full
This is the device ID currently advertised by the tracker.
The Ad Record Type byte indicates the format of the remaining bytes to follow in the advertisement data (the Ad Record Data).
The list of defined Ad Record Types and corresponding data format is displayed in the following table (Table 7).
Table 7: 0x10 - Ad Tracking Record
Field Name
Size (Bytes)
Data Type
Description
Profile
1
uint8
User programmable device type category
Epoch Time
4
uint32
Time since a known reference point in seconds
TX Power
1
int8
TX power setting of the radio (-40 to 8)
Motion
1
uint8
0: No motion present, 1: Motion present
HW Model ID
1
uint8
0x00
– BT510
0x10
– BL654 DVK
0x20
– BL653 DVK
0x30
– BT710
0x40
– MG100