![Laird DVK-BL600-SA User Manual Download Page 13](http://html.mh-extra.com/html/laird/dvk-bl600-sa/dvk-bl600-sa_user-manual_670509013.webp)
BL600 Development Kit
Version 2.0
Americas: +1-800-492-2320 Option 2
Europe: +44-1628-858-940
Hong Kong: +852-2923-0610
www.lairdtech.com/bluetooth
13
CONN-GUIDE_BL600_DVK_v2_0
5.1.1
JP2 SIO_0-7
In the
smart
BASIC application code written to use sensors on the development board (including the Temperature
sensor - U1, Trim Pot - R9, Buzzer - U2, LED0 - D1, LED1 - D2, Button0 - SW1, and Button1 - SW3), the SIO pins
direction and type (that these sensors are connected to, SIO_4, SIO_5, SIO_15, SIO_18, SIO_19, SIO_16, SIO_17
respectively) must be set in the
smart
BASIC application to override the defaults in the BL600 firmware.
Pin
Designation
Default
Function
1
Alternate
Function
2
Default
Direction
3
Comment
SIO_0
DIO
-
Input
SIO_1
DIO
AIN
Input
8, 9, 10 bit resolution – voltage scaling
SIO_2
DIO
AIN
Input
8, 9, 10 bit resolution – voltage scaling
SIO_3
DIO
AIN
Input
8, 9, 10 bit resolution – voltage scaling
SIO_4
DIO
AIN
Input
8, 9, 10 bit resolution – voltage scaling
SIO_5
DIO
AIN
Input
8, 9, 10 bit resolution – voltage scaling
SIO_6
DIO
AIN
Input
8, 9, 10 bit resolution – voltage scaling
SIO_7
DIO
AIN
Input
1
DIO: Digital Input or Output
2
AIN: Analog Input
3
Default Direction In BL600 module
smart
BASIC runtime engine FW
5.1.2
JP3 SIO_8-15
Pin
Designation
Default
Function
1
Alternate
Function
Default
Direction
3
Comment
SIO_8
DIO
I2C_SDA
Input
SIO_9
DIO
I2C_SCL
Input
SIO_10
DIO
SPI_MOSI
Input
SPI_MOSI is an output in SPI master mode
SIO_11
DIO
SPI_MISO
Input
SIO_12
DIO
SPI_CLK
Input
SPI_CLK is an output in SPI master mode
SIO_13
DIO
Input
SIO_14
DIO
Input
SIO_15
DIO
Input
Connects to BUZZER output on DVK
1
DIO: Digital Input or Output
2
AIN: Analog Input
3
Default Direction In BL600 module
smart
BASIC runtime engine FW
5.1.3
JP4 SIO_16-19
Pin
Designation
Default
Function
1
Alternate
Function
Default
Direction
3
Comment
SIO_16
DIO
Input
Input for BUTTON 0 (SW1) on DVK
SIO_17
DIO
Input
Input to BUTTON 1 (SW3) on DVK
SIO_18
DIO
Input
Connects to LED 0 on DVK
SIO_19
DIO
Input
Connects to LED 1 on DVK
1
DIO: Digital Input or Output
2
AIN: Analog Input
3
Default Direction In BL600 module
smart
BASIC runtime engine FW
Note: SIO_20 is a No Connect (N/C) and is reserved by Laird for future use.