TESTING THE AUTOMATIC GAS VALVE AND BURNER CONTROL SYSTEM
NOTE:
A smoky, strong smelling vapor fills the cooking compartment and exhaust ports
during initial startup. This condition is normal, please refer to Initial Operation and Cleaning,
at the end of this chapter.
The unit is now ready for operation.
• If this test is part of the initial installation START-UP CHECKS, continue the check list
with step 14.
• If this is part of component repair, perform START-UP CHECK number 14 only.
If the unit passes the check, it is ready to resume normal cooking operation.
WARNING
DO NOT TRY TO LIGHT THE BURNERS OR PILOT WITH A FLAME.
THERE IS NO PILOT TO LIGHT OR ADJUST.
The Combis have electronic ignition systems which automatically light the burners,
sense the flame, and control gas flow. This provides both precise burner control and
safety ignition and shutdown features.
DEATH, INJURY OR EQUIPMENT DAMAGE may result from an improperly adjusted gas
control and ignition system. Do not alter any adjustments on this electronic control
or solenoid valve. If adjustment is required, contact an authorized service center. The
Manufacturer is in no way responsible for the operation or safety of this equipment
if the controller, valve, or igniter probe are adjusted by anyone other than authorized
service representative.
53
90028771rev00
Figure 2-9:
automatic gas valve
7
-