Maintenance
32
Digital Read Out (DRO) is displaying an error.
Err1: Over-current mode.
If the operating current of the motor exceeds 18 Amps
for 30 seconds, the control board goes into Over-current
protection mode.
Over-current mode is to stop the motor immediately and
the display shows Err1.
Release the Over-current mode steps:
•
Press the stop button to release the Over-
current mode.
•
Press the Start button again and the control
board restarts the motor.
Err2: Motor work fail mode.
After pressing the start button, if the motor is not running
after 25seconds, the control board enters the Motor
work fail mode.
In the motor work fail mode, the control board
immediately stops the motor operation, and the display
shows Err2.
Release the Motor work fail mode steps:
•
Press the stop button to release the Motor work
fail mode.
•
Press the Start button again and the control
board restarts the motor.
Err3: Spindle work fail mode.
After pressing the start button, if the control board
detects that the spindle is not running for 30 seconds
after the motor runs normally, it will enter the Spindle
work fail mode.
In the Spindle work fail mode, the control board
immediately stops the motor, and the display shows
Err3.
Release the Spindle work fail mode steps:
•
Press the stop button to release the Spindle
work fail mode.
•
Press the Start button again and the control
board restarts the motor.
Summary of Contents for REVO 15
Page 4: ...Safety 4 Warranty Support...
Page 14: ...Dimensions 14 64 7 1643 7 24 4 618 5 60 9 1546 7 24 4 618 5 OPTIONAL Mobility Kit...
Page 23: ...Set Up 23 Rear Wheel Assembly Front Wheel Assembly OPTIONAL Mobility Kit...
Page 35: ...Parts 35 Tailstock Banjo Tool Rest...
Page 36: ...Parts 36 Bed Leg Assembly...